Analyze trace-levels of inorganic anions and organic acids using isocratic or gradient methods with the Thermo Scientific™ Dionex™ IonPac™ AS10 IC Column. Its high capacity permits the analysis of trace-level analytes in high-ionic-strength matrices. Use the Dionex IonPac AS10 column for the analysis of inorganic anions in high nitrate samples.
 
Catalog Number
043118
Unit Size
Each 1
dimColumnType
Diameter (Metric)
4 mm
Length (Metric)
250 mm
Price (USD)
Full specifications
Packing MaterialEthylvinylbenzene/Divinylbenzene
Column Capacity170 µeq
Column ChemistryHydroxide
Flow Rate1.0 to 2.0 mL/min.
For Use With (Application)Separation of Inorganic Anions and Organic Acids
For Use With (Equipment)Eluent Generator
Ion Exchange GroupAlkanol Quaternary Ammonium Ion
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size8.5 µm
Stationary PhaseIonPac AS10
TypeStandard Bore Analytical Column
pH0 to 14
Length (Metric)250 mm
Diameter (Metric)4 mm
Pore Size2000 &‌Aring;
Latex Crosslinking5%
Diameter (Metric) Latex65 nm
Crosslinking55% DVB
Anion Exchange Capacity170 µeq
Solvents0 to 100% of HPLC Solvents
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
dimColumnType
Diameter (Metric)
2 mm
Length (Metric)
250 mm
Price (USD)
Full specifications
Packing MaterialEthylvinylbenzene/Divinylbenzene
Column Capacity42.5 µeq
Column ChemistryHydroxide
Flow Rate0.25 to 0.5 mL/min.
For Use With (Application)Separation of Inorganic Anions and Organic Acids
For Use With (Equipment)Eluent Generator
Ion Exchange GroupAlkanol Quaternary Ammonium Ion
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size8.5 µm
Stationary PhaseIonPac AS10
TypeMicrobore Analytical Column
pH0 to 14
Length (Metric)250 mm
Diameter (Metric)2 mm
Pore Size2000 &‌Aring;
Latex Crosslinking5%
Diameter (Metric) Latex65 nm
Crosslinking55% DVB
Anion Exchange Capacity42.5 µeq
Solvents0 to 100% of HPLC Solvents
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
dimColumnType
Diameter (Metric)
2 mm
Length (Metric)
50 mm
Price (USD)
Full specifications
Column ChemistryHydroxide
For Use With (Application)Separation of Inorganic Anions and Organic Acids, Anion Exchange
For Use With (Equipment)Separation of Inorganic Anions and Organic Acids
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% Typical HPLC Solvents
Particle Size13 µm
Stationary PhaseIonPac AG10
TypeMicrobore Guard Column
Length (Metric)50 mm
Diameter (Metric)2 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
dimColumnType
Diameter (Metric)
4 mm
Length (Metric)
50 mm
Price (USD)
Full specifications
Column ChemistryHydroxide
For Use With (Application)Separation of Inorganic Anions and Organic Acids
For Use With (Equipment)Separation of Inorganic Anions and Organic Acids
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% Typical HPLC Solvents
Particle Size13 µm
Stationary PhaseIonPac AS10
TypeStandard Bore Guard Column
Length (Metric)50 mm
Diameter (Metric)4 mm
Unit SizeEach 1
Showing 4 of 4
Catalog NumberSpecificationsUnit SizedimColumnTypeDiameter (Metric)Length (Metric)Price (USD)
043118Full specifications
Each 14 mm250 mmContact Us ›
Packing MaterialEthylvinylbenzene/Divinylbenzene
Column Capacity170 µeq
Column ChemistryHydroxide
Flow Rate1.0 to 2.0 mL/min.
For Use With (Application)Separation of Inorganic Anions and Organic Acids
For Use With (Equipment)Eluent Generator
Ion Exchange GroupAlkanol Quaternary Ammonium Ion
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size8.5 µm
Stationary PhaseIonPac AS10
TypeStandard Bore Analytical Column
pH0 to 14
Length (Metric)250 mm
Diameter (Metric)4 mm
Pore Size2000 &‌Aring;
Latex Crosslinking5%
Diameter (Metric) Latex65 nm
Crosslinking55% DVB
Anion Exchange Capacity170 µeq
Solvents0 to 100% of HPLC Solvents
Unit SizeEach 1
043123Full specifications
Each 12 mm250 mmContact Us ›
Packing MaterialEthylvinylbenzene/Divinylbenzene
Column Capacity42.5 µeq
Column ChemistryHydroxide
Flow Rate0.25 to 0.5 mL/min.
For Use With (Application)Separation of Inorganic Anions and Organic Acids
For Use With (Equipment)Eluent Generator
Ion Exchange GroupAlkanol Quaternary Ammonium Ion
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size8.5 µm
Stationary PhaseIonPac AS10
TypeMicrobore Analytical Column
pH0 to 14
Length (Metric)250 mm
Diameter (Metric)2 mm
Pore Size2000 &‌Aring;
Latex Crosslinking5%
Diameter (Metric) Latex65 nm
Crosslinking55% DVB
Anion Exchange Capacity42.5 µeq
Solvents0 to 100% of HPLC Solvents
Unit SizeEach 1
043124Full specifications
Each 12 mm50 mmContact Us ›
Column ChemistryHydroxide
For Use With (Application)Separation of Inorganic Anions and Organic Acids, Anion Exchange
For Use With (Equipment)Separation of Inorganic Anions and Organic Acids
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% Typical HPLC Solvents
Particle Size13 µm
Stationary PhaseIonPac AG10
TypeMicrobore Guard Column
Length (Metric)50 mm
Diameter (Metric)2 mm
Unit SizeEach 1
043119Full specifications
Each 14 mm50 mmContact Us ›
Column ChemistryHydroxide
For Use With (Application)Separation of Inorganic Anions and Organic Acids
For Use With (Equipment)Separation of Inorganic Anions and Organic Acids
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% Typical HPLC Solvents
Particle Size13 µm
Stationary PhaseIonPac AS10
TypeStandard Bore Guard Column
Length (Metric)50 mm
Diameter (Metric)4 mm
Unit SizeEach 1
Showing 4 of 4
Superior Chromatographic Performance in High Nitrate Samples
  • Excellent resolution of weakly retained low-molecular-weight aliphatic acids
  • Selectivity and high capacity for analysis of trace-level analytes in high-ionic-strength matrices
  • Strongly retains nitrate for high-resolution analysis of trace anions in nitric acid and nitrate salts
For Best Results
  • Use a Dionex eluent generator for simplified eluent preparation for applications using less than 100mN hydroxide
  • Use the Thermo Scientific™ Dionex™ Anion Self-Regenerating Suppressor (ASRS™ 300) with the Dionex IonPac AS10 column for continuous suppression of traditional eluents and more concentrated eluents up to 200mM NaOH
Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.