Informational:This product is now available for online ordering in the U.S. and Canada—Learn more »
Thermo Scientific™

Dionex™ CarboPac™ PA10 IC Columns

Catalog number: 057180
Thermo Scientific™

Dionex™ CarboPac™ PA10 IC Columns

Catalog number: 057180
For isocratic separations of mono- and disaccharides in foods, drugs, and plants, the Thermo Scientific™ Dionex™ CarboPac™ PA10 Capillary, Analytical & Guard Column provides superior selectivity. Combined with pulsed amperometric detection (PAD), this anion-exchange column delivers high-resolution separations. It is an ideal choice for separating mono- and disaccharides in mammalian glycoproteins. The column efficiently resolves fucose from the system void and from protein hydrolysate interferents. Oxygen elutes after mannose, eliminating interference with monosaccharides.
 
Catalog Number
057180
Unit Size
Each 1
dimColumnType
Diameter (Metric)
2 mm
Length (Metric)
250 mm
Price (USD)
Full specifications
Column Capacity25 µeq
Flow Rate0.25 mL/min.
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)HPAE-PAD
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, Up to 90% of Common HPLC Solvents
Particle Size10 µm
Stationary PhaseCarboPac PA10
TypeMicrobore Analytical Column
Length (Metric)250 mm
Diameter (Metric)2 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
dimColumnType
Diameter (Metric)
2 mm
Length (Metric)
50 mm
Price (USD)
Full specifications
Column Capacity5 µeq
Flow Rate0.25 mL/min.
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)HPAE-PAD
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, Up to 90% of Common HPLC Solvents
Particle Size10 µm
Stationary PhaseCarboPac PA10
TypeMicrobore Guard Column
Length (Metric)50 mm
Diameter (Metric)2 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
dimColumnType
Diameter (Metric)
4 mm
Length (Metric)
250 mm
Price (USD)
Full specifications
Column Capacity100 µeq
Flow Rate1.0 mL/min.
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)HPAE-PAD
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, Up to 90% of Common HPLC Solvents
Particle Size10 µm
Stationary PhaseCarboPac PA10
TypeStandard Bore Analytical Column
Length (Metric)250 mm
Diameter (Metric)4 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
dimColumnType
Diameter (Metric)
4 mm
Length (Metric)
50 mm
Price (USD)
Full specifications
Column Capacity20 µeq
Flow Rate1.0 mL/min.
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)HPAE-PAD
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, Up to 90% of Common HPLC Solvents
Particle Size10 µm
Stationary PhaseCarboPac PA10
TypeStandard Bore Guard Column
Length (Metric)50 mm
Diameter (Metric)4 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
dimColumnType
Diameter (Metric)
0.4 mm
Length (Metric)
250 mm
Price (USD)
Full specifications
Column Capacity1 µeq
Flow Rate0.01 mL/min.
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)HPAE-PAD
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 90% HPLC Solvents
Particle Size10 µm
Stationary PhaseCarboPac PA10
TypeCapillary Column
pH0 to 14
Length (Metric)250 mm
Diameter (Metric)0.4 mm
Anion Exchange Capacity1 µeq/Column
SolventsUp to 90% of Common HPLC Solvents
Resin Composition10 µm Diameter Substrate (Ethylvinylbenzene 55% Crosslinked with Divinylbenzene) Agglomerated with 460 nm MicroBead Difunctional Quaternary Ammonium Ion (5% Crosslinked)
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
dimColumnType
Diameter (Metric)
0.4 mm
Length (Metric)
50 mm
Price (USD)
Full specifications
Flow Rate0.010 mL/min.
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)HPAE-PAD
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 90% HPLC Solvents
Particle Size10 µm
Stationary PhaseCarboPac PA10 IC
TypeCapillary Guard
Length (Metric)50 mm
Diameter (Metric)0.4 mm
Unit SizeEach 1
Showing 6 of 6
Catalog NumberSpecificationsUnit SizedimColumnTypeDiameter (Metric)Length (Metric)Price (USD)
057180Full specifications
Each 12 mm250 mmContact Us ›
Column Capacity25 µeq
Flow Rate0.25 mL/min.
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)HPAE-PAD
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, Up to 90% of Common HPLC Solvents
Particle Size10 µm
Stationary PhaseCarboPac PA10
TypeMicrobore Analytical Column
Length (Metric)250 mm
Diameter (Metric)2 mm
Unit SizeEach 1
057181Full specifications
Each 12 mm50 mmContact Us ›
Column Capacity5 µeq
Flow Rate0.25 mL/min.
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)HPAE-PAD
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, Up to 90% of Common HPLC Solvents
Particle Size10 µm
Stationary PhaseCarboPac PA10
TypeMicrobore Guard Column
Length (Metric)50 mm
Diameter (Metric)2 mm
Unit SizeEach 1
046110Full specifications
Each 14 mm250 mmContact Us ›
Column Capacity100 µeq
Flow Rate1.0 mL/min.
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)HPAE-PAD
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, Up to 90% of Common HPLC Solvents
Particle Size10 µm
Stationary PhaseCarboPac PA10
TypeStandard Bore Analytical Column
Length (Metric)250 mm
Diameter (Metric)4 mm
Unit SizeEach 1
046115Full specifications
Each 14 mm50 mmContact Us ›
Column Capacity20 µeq
Flow Rate1.0 mL/min.
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)HPAE-PAD
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, Up to 90% of Common HPLC Solvents
Particle Size10 µm
Stationary PhaseCarboPac PA10
TypeStandard Bore Guard Column
Length (Metric)50 mm
Diameter (Metric)4 mm
Unit SizeEach 1
082320Full specifications
Each 10.4 mm250 mmContact Us ›
Column Capacity1 µeq
Flow Rate0.01 mL/min.
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)HPAE-PAD
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 90% HPLC Solvents
Particle Size10 µm
Stationary PhaseCarboPac PA10
TypeCapillary Column
pH0 to 14
Length (Metric)250 mm
Diameter (Metric)0.4 mm
Anion Exchange Capacity1 µeq/Column
SolventsUp to 90% of Common HPLC Solvents
Resin Composition10 µm Diameter Substrate (Ethylvinylbenzene 55% Crosslinked with Divinylbenzene) Agglomerated with 460 nm MicroBead Difunctional Quaternary Ammonium Ion (5% Crosslinked)
Unit SizeEach 1
082321Full specifications
Each 10.4 mm50 mmContact Us ›
Flow Rate0.010 mL/min.
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)HPAE-PAD
Max. Pressure4000 psi (275 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 90% HPLC Solvents
Particle Size10 µm
Stationary PhaseCarboPac PA10 IC
TypeCapillary Guard
Length (Metric)50 mm
Diameter (Metric)0.4 mm
Unit SizeEach 1
Showing 6 of 6
Dionex CarboPac PA10 Columns consist of 10µm diameter nonporous beads covered with a fine latex of functionalized Thermo Scientific™ Dionex™ MicroBead™ resin. This pellicular resin structure permits excellent mass transfer, resulting in high-resolution chromatography and rapid re-equilibration.

Sensitive Analysis of Mono- and Disaccharides
  • Ideal for the quantification of acidic, neutral, and aminomonosaccharides
  • Well suited for separation of sialic acids when sodium acetate added to the eluent
  • Simple isocratic separations
  • No derivatization required
  • Gradient compatible
  • Available in capillary, microbore, and standard bore formats

About the Dionex CarboPac Family of Columns

The Dionex CarboPac family offers a selection of high-performance liquid chromatography (HPLC) columns, each optimized for a different class of compounds. Combined with PAD, which provides a means to detect carbohydrates without derivatization, these columns support simple, reliable techniques to separate sugar alcohols, mono- and disaccharides, and poly- and oligosaccharides.

Dionex CarboPac columns provide high-resolution separations of:

  • Glycoprotein oligosaccharides and complex carbohydrates from dietary fiber, including fructans, maltodextrins, and amylopectins
  • Monosaccharides, such as those obtained from glycoprotein hydrolysates or plant hydrolysates
  • Mono- and disaccharides
Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.