Thermo Scientific™

Dionex™ ICS-Series PDA Photodiode Array Detector

Catalog number: 074114
Thermo Scientific™

Dionex™ ICS-Series PDA Photodiode Array Detector

Catalog number: 074114

Maximize optical absorbance information with the Thermo Scientific™ Dionex™ ICS-Series PDA Photodiode Array Detector. You will get excellent, high-resolution performance from its full UV-vis spectra, along with an ultraquiet optical bench. A variety of flow cells compatible with ion chromatography are available.

 
Catalog Number
074114
Unit Size
Each
Type
Photodiode Array Detector
For Use With (Application)
Ion Chromatography
Pixel Resolution
0.7 nm
Wavelength Range
190 to 800 nm
Price (USD)
Full specifications
For Use With (Application)Ion Chromatography
Analog OutputsFour: 0-3 Å, 1000 mV Range
For Use With (Equipment)Dionex Chromeleon Chromatography Data System Software
TypePhotodiode Array Detector
Detection ModeWavelength Resolution/UV-Visibility
Detector TypeUV-Visibility
Drift<500 µÅ/h
Noise Level±10 µÅ at 254 nm (flowing water, 2-s rise time)
±15 µÅ at 520 nm (flowing water, 2-s rise time)
Flow Cell Max. Pressure<2 MPa (300 psi) PEEK
<3 MPa (500 psi) SST
Flow Cell Volume13 µL
Pixel Resolution0.7 nm
Flow Cell MaterialsPEEK, Fused Silica, SST
Wavelength Accuracy±1 nm, self-calibration with deuterium lines, verification with built-in holmium oxide filter
Wavelength Range190 to 800 nm
LampTungsten and deuterium
Linearity>2 Å
Height (Metric)17.4 cm
Length (Metric)50.3 cm
Width (Metric)44.4 cm
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizeTypeFor Use With (Application)Pixel ResolutionWavelength RangePrice (USD)
074114Full specifications
EachPhotodiode Array DetectorIon Chromatography0.7 nm190 to 800 nmRequest A Quote
For Use With (Application)Ion Chromatography
Analog OutputsFour: 0-3 Å, 1000 mV Range
For Use With (Equipment)Dionex Chromeleon Chromatography Data System Software
TypePhotodiode Array Detector
Detection ModeWavelength Resolution/UV-Visibility
Detector TypeUV-Visibility
Drift<500 µÅ/h
Noise Level±10 µÅ at 254 nm (flowing water, 2-s rise time)
±15 µÅ at 520 nm (flowing water, 2-s rise time)
Flow Cell Max. Pressure<2 MPa (300 psi) PEEK
<3 MPa (500 psi) SST
Flow Cell Volume13 µL
Pixel Resolution0.7 nm
Flow Cell MaterialsPEEK, Fused Silica, SST
Wavelength Accuracy±1 nm, self-calibration with deuterium lines, verification with built-in holmium oxide filter
Wavelength Range190 to 800 nm
LampTungsten and deuterium
Linearity>2 Å
Height (Metric)17.4 cm
Length (Metric)50.3 cm
Width (Metric)44.4 cm
Unit SizeEach
Showing 1 of 1

High-Performance UV-Vis Detection

  • Outstanding wavelength resolution from a 1024-element photodiode array
  • Broad wavelength range from 190 to 800 nm
  • Low noise and high intensity over the full spectral range from the deuterium and tungsten lamps
  • Simple installation and data collection via USB
  • Alternate data collection via four analog outputs
  • Excellent reliability and reproducibility with low baseline drift

Excellent Ease of Use

  • Easy verification of wavelength accuracy with built-in holmium oxide filter
  • Simplified routine maintenance with front access to prealigned cells and lamps
  • Convenient quick view of detector status on five front-panel LEDs
  • Powerful full control and data collection through Thermo Scientific™ Dionex™ Chromeleon™ Chromatography Data System software
  • User-friendly software panels for operation in multiwavelength mode
  • Limited stand-alone operation without software control for simplified troubleshooting or temporary operation without a computer