Separate haloacetic acids and bromate in drinking water samples with high sensitivity using the Thermo Scientific™ Dionex™ IonPac™ AS24A column. When this high-capacity hydroxide-selective anion-exchange column is used for the first dimension of separation in the two dimensional IC (2D-IC) method, low µg/L (ppb) levels of haloacetic acids can be detected. The Dionex IonPac AS24A column is also ideal for the development of specialized applications, providing excellent separation of environmental anions including inorganic anions, oxyhalides, oxyanions, and organic acids in complex matrices.
 
Catalog Number
076010
Unit Size
Each 1
dimColumnType
Diameter (Metric)
4 mm
Length (Metric)
250 mm
Price (USD)
Full specifications
Packing MaterialPolymeric
Certifications/ComplianceSpecified Column for US EPA Method 557 (2 x 250 mm)
Column Capacity140 µeq
Column ChemistryHydroxide
Flow Rate1.0 to 2.0 mL/min.
For Use With (Application)Separation of Haloacetic Acids and Bromate in Drinking Water, Anion Exchange
For Use With (Equipment)Thermo Scientific Dionex ICS-5000+ RFIC System Equipped with an Eluent Generator
HydrophobicityUltralow
Ion Exchange GroupAlkanol Quaternary Ammonium Ion
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size7 µm
Stationary PhaseIonPac AS24A
TypeStandard Bore Analytical Column
pH0 to 14
Length (Metric)250 mm
Diameter (Metric)4 mm
Pore Size2000 &‌Aring;
Crosslinking55% DVB
Column ConstructionPEEK
Solvents0 to 100% of HPLC Solvents
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
dimColumnType
Diameter (Metric)
2 mm
Length (Metric)
250 mm
Price (USD)
Full specifications
Column Capacity140 µeq
For Use With (Application)Separation of Haloacetic Acid Anions in Drinking Water Samples
For Use With (Equipment)Thermo Scientific Dionex ICS-5000+ RFIC System Equipped with an Eluent Generator
HydrophobicityUltralow
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size7 µm
Stationary PhaseIonPac AS24A
TypeAnalytical Column
Length (Metric)250 mm
Diameter (Metric)2 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
dimColumnType
Diameter (Metric)
0.4 mm
Length (Metric)
250 mm
Price (USD)
Full specifications
Column Capacity5.6 µeq
For Use With (Application)Separation of Haloacetic Acid Anions in Drinking Water Samples
For Use With (Equipment)Thermo Scientific Dionex ICS-5000+ RFIC System Equipped with an Eluent Generator
HydrophobicityUltralow
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size7 µm
Stationary PhaseIonPac AS24A
TypeCapillary Column
Length (Metric)250 mm
Diameter (Metric)0.4 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
dimColumnType
Diameter (Metric)
4 mm
Length (Metric)
50 mm
Price (USD)
Full specifications
Column Capacity6 µeq
For Use With (Application)Separation of Haloacetic Acids and Bromate in Drinking Water, Anion Exchange
For Use With (Equipment)4 mm Dionex IonPac AS24A Column
HydrophobicityUltralow
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size11 µm
Stationary PhaseIonPac AG24A
TypeStandard Bore Guard Column
Length (Metric)50 mm
Diameter (Metric)4 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
dimColumnType
Diameter (Metric)
2 mm
Length (Metric)
50 mm
Price (USD)
Full specifications
Column Capacity1.5 µeq
Flow Rate12 μL/min.
For Use With (Application)Separation of Haloacetic Acid Anions in Drinking Water Samples
For Use With (Equipment)Thermo Scientific Dionex ICS-5000+ RFIC System Equipped with an Eluent Generator
HydrophobicityUltralow
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size11 µm
Stationary PhaseIonPac AS24A
TypeMicrobore Guard Column
Length (Metric)50 mm
Diameter (Metric)2 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
dimColumnType
Diameter (Metric)
0.4 mm
Length (Metric)
50 mm
Price (USD)
Full specifications
Column Capacity0.06 µeq
For Use With (Application)Separation of Haloacetic Acid Anions in Drinking Water Samples
For Use With (Equipment)Thermo Scientific Dionex ICS-5000+ RFIC System Equipped with an Eluent Generator
HydrophobicityUltralow
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size11 µm
Stationary PhaseIonPac AS24A
TypeCapillary Guard Column
Length (Metric)50 mm
Diameter (Metric)0.4 mm
Unit SizeEach 1
Showing 6 of 6
Catalog NumberSpecificationsUnit SizedimColumnTypeDiameter (Metric)Length (Metric)Price (USD)
076010Full specifications
Each 14 mm250 mmContact Us ›
Packing MaterialPolymeric
Certifications/ComplianceSpecified Column for US EPA Method 557 (2 x 250 mm)
Column Capacity140 µeq
Column ChemistryHydroxide
Flow Rate1.0 to 2.0 mL/min.
For Use With (Application)Separation of Haloacetic Acids and Bromate in Drinking Water, Anion Exchange
For Use With (Equipment)Thermo Scientific Dionex ICS-5000+ RFIC System Equipped with an Eluent Generator
HydrophobicityUltralow
Ion Exchange GroupAlkanol Quaternary Ammonium Ion
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size7 µm
Stationary PhaseIonPac AS24A
TypeStandard Bore Analytical Column
pH0 to 14
Length (Metric)250 mm
Diameter (Metric)4 mm
Pore Size2000 &‌Aring;
Crosslinking55% DVB
Column ConstructionPEEK
Solvents0 to 100% of HPLC Solvents
Unit SizeEach 1
078112Full specifications
Each 12 mm250 mmContact Us ›
Column Capacity140 µeq
For Use With (Application)Separation of Haloacetic Acid Anions in Drinking Water Samples
For Use With (Equipment)Thermo Scientific Dionex ICS-5000+ RFIC System Equipped with an Eluent Generator
HydrophobicityUltralow
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size7 µm
Stationary PhaseIonPac AS24A
TypeAnalytical Column
Length (Metric)250 mm
Diameter (Metric)2 mm
Unit SizeEach 1
082536Full specifications
Each 10.4 mm250 mmContact Us ›
Column Capacity5.6 µeq
For Use With (Application)Separation of Haloacetic Acid Anions in Drinking Water Samples
For Use With (Equipment)Thermo Scientific Dionex ICS-5000+ RFIC System Equipped with an Eluent Generator
HydrophobicityUltralow
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size7 µm
Stationary PhaseIonPac AS24A
TypeCapillary Column
Length (Metric)250 mm
Diameter (Metric)0.4 mm
Unit SizeEach 1
076011Full specifications
Each 14 mm50 mmContact Us ›
Column Capacity6 µeq
For Use With (Application)Separation of Haloacetic Acids and Bromate in Drinking Water, Anion Exchange
For Use With (Equipment)4 mm Dionex IonPac AS24A Column
HydrophobicityUltralow
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size11 µm
Stationary PhaseIonPac AG24A
TypeStandard Bore Guard Column
Length (Metric)50 mm
Diameter (Metric)4 mm
Unit SizeEach 1
082535Full specifications
Each 12 mm50 mmContact Us ›
Column Capacity1.5 µeq
Flow Rate12 μL/min.
For Use With (Application)Separation of Haloacetic Acid Anions in Drinking Water Samples
For Use With (Equipment)Thermo Scientific Dionex ICS-5000+ RFIC System Equipped with an Eluent Generator
HydrophobicityUltralow
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size11 µm
Stationary PhaseIonPac AS24A
TypeMicrobore Guard Column
Length (Metric)50 mm
Diameter (Metric)2 mm
Unit SizeEach 1
078115Full specifications
Each 10.4 mm50 mmContact Us ›
Column Capacity0.06 µeq
For Use With (Application)Separation of Haloacetic Acid Anions in Drinking Water Samples
For Use With (Equipment)Thermo Scientific Dionex ICS-5000+ RFIC System Equipped with an Eluent Generator
HydrophobicityUltralow
Max. Pressure3000 psi (207 bar)
Mobile Phase CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size11 µm
Stationary PhaseIonPac AS24A
TypeCapillary Guard Column
Length (Metric)50 mm
Diameter (Metric)0.4 mm
Unit SizeEach 1
Showing 6 of 6
Optimized for 2D-IC Determination of Haloacetic Acids
  • Designed for separation using the Dionex IonPac AS24A 4x250mm column for the first dimension prior to using the Dionex IonPac AS26 capillary column for the second dimension
  • Minimal baseline shifts and enhanced analyte sensitivity can be obtained using the Thermo Scientific™ Dionex™ Anion Self-Regenerating Suppressor (ASRS™ 300)
Increase Mass Sensitivity and Conserve Eluent

The Dionex IonPac AS24A Capillary column offers users excellent retention time and reproducibility in addition to increased mass sensitivity and eluent conservation.

Superior Chromatographic Performance
  • High capacity–560µeq per column (4x250mm)–allows injection of complex matrices without overloading the column while maintaining excellent peak shapes for lower concentration analytes
  • Sample pretreatment is not required when determining haloacetic acids in high-ionic strength matrices
  • The column is ideal for development of specialized applications using Reagent-Free™ Ion Chromatography (RFIC™) systems with gradient elution.
  • Can be operated at ambient or elevated temperatures; selectivity is optimized for a 15ºC operating temperature to ensure reproducible recovery for haloacetic acids
  • Compatibility with HPLC organic solvents provides operational flexibility and ease of cleanup
Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.