Detection Limits | 1.5 ppb (60 sec. averaging time) |
Flow Rate | 0.8 L/min. |
Inputs | 16 Inputs (TLL), 4 Isolated Voltage Inputs 0 to 10 V |
Linearity | ±0.25% full scale |
Response Time | 20 sec. (10 sec. averaging) (Photometer), <180 sec. (Ozonator Response Time) |
Span Drift | <1% full scale (1 month) |
Temperature (English) Operating | 32°F to 113°F |
Temperature (Metric) Operating | 0°C to 45°C |
Zero Noise | 0.75 ppb RMS (60 sec. averaging time) |
Accuracy | ±0.8% of reading +0.2% of full-scale |
Certifications/Compliance | CE, TUV-SUD Safety, UKCA |
Communication Ports | Serial ports: 1 RS-232/485 port 1 RS-485 external accessory port Other ports: 3 Full Speed USB ports (one in front, two in rear) 1 Gigabit ethernet port Communication: MODBUS, Streaming, Gesytec (Bayern-Hessen) |
Depth (English) | 24 in. |
Depth (Metric) | 609 mm |
Description | 146iQ Multi-Gas Calibrator |
Electrical Requirements | 100-240 VAC 50/60 Hz, 275 watts |
Height (English) | 8.72 in. |
Height (Metric) | 221.48 mm |
Outputs | 6 Isolated voltages outputs 6 Isolated analog current outputs |
Precision | 1 ppb |
Repeatability of Flow Control | ±0.2% of full scale |
Voltage | 100/240 V |
Weight (English) | 43 lb. (with 3 MFCs, Ozonator, and Photometer) |
Weight (Metric) | 19.5 kg (with 3 MFCs, Ozonator, and Photometer) |
Width (English) | 16.75 in. |
Width (Metric) | 425.45 mm |
Zero Drift | <1.0 ppb (24 hours) |
Unit Size | Each |
Catalog Number | Specifications | Unit Size | Description | Price (USD) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
146IQ | Each | 146iQ Multi-Gas Calibrator | Request A Quote | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Discover the non-stop intelligence of the iQ Series Gas Analyzer now with a two-year warranty. Our next generation platform of gas analyzers includes:
Predictive Diagnostics
Address problems before they occur with improved serviceability and plug and play components. 24/7 access to your analyzer’s information helps minimize troubleshooting time with innovative, interchangeable DMC modules in a highly precise, yet tough solution.
Proactive Communications
Maintain optimum performance through iQ360 and email alerts. When subscribed to iQ360 service, your instrument communicates directly to our technical support team upon alarm activation. Our technical support team develops a corrective plan and emails it to your staff. Eliminate surprises and take control of your day with the iQ Series Gas Analyzers.
Personal Device Connectivity
Real time, continuous remote monitoring is now possible with the iQ companion mobile device app. The iQ app allows for remote monitoring of iQ gas analyzers, simplified ways of getting in touch with us, and instant access to both maintenance alerts and product documentation.