Multiskan FC brings together over 40 years experience of the well-known Multiskan product brand, with features for enhanced usability. The Multiskan FC has a 340–850 nm wavelength range, enabling a wide variety of applications from enzyme kinetic studies to Lowry assays. The instrument provides fast and accurate measurements enabling complete 96-well plate reading in less than seven seconds. The instrument is also equipped with linear shaking as standard. A model with an incubator enables incubation temperatures up to 50°C and the capacity to read 384-well plates. SkanIt software supports optimal use of the instrument with a visual workflow, effortless data analysis and exporting capabilities.
 
Catalog Number
51119000
Unit Size
Each
Description
Multiskan FC
Plate Type
96-well plates
Price (USD)
Availability
-
Full specifications
Quantity
-
DescriptionMultiskan FC
Plate Type96-well plates
Wavelength SelectionFilters
Wavelength Range340 to 850nm
Filters8-position filter wheel; filters installed: 405nm, 450nm, and 620nm
Linearity0–3 Abs, ± 2% at 405nm, 96-well plate
Resolution0.001 Abs
Accuracy± 1% (0–3 Abs) or ± 0.003 Abs, which ever is greater at 405nm
PrecisionCV ≤ 0.2% (0.3–3 Abs) at 405nm
Incubator TemperatureUp to 50°C
ShakingLinear
Measurement Speed7 seconds, 96-well plate, fast mode; 13 seconds, 96-well plate, normal mode
Depth (Metric)40cm
Depth (English)15.7 in.
Width (Metric)29cm
Width (English)11.4 in.
Height (Metric)22cm
Height (English)8.7 in.
CompatibilityRobot
Warranty1 Year
Detector TypePhotodetector
Light SourceQuartz-halogen lamp
Reading Options96 Well Plate; 384 Well Plate
Read-out Range0 to 6 Abs
Software TypeSkanIt Software
Product LineMultiskan™
InterfaceUser: On-board or PC control
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Accessory - Lamp 6V/10W
Plate Type
----
Price (USD)
Price: 263.00
Your Price:
Availability
-
Full specifications
Quantity
DescriptionAccessory - Lamp 6V/10W
Plate Type----
Light SourceLamp
Software TypeSkanIt Software
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Multiskan FC with incubator
Plate Type
96- and 384-well plates
Price (USD)
Availability
-
Full specifications
Quantity
-
DescriptionMultiskan FC with incubator
Plate Type96- and 384-well plates
Wavelength SelectionFilters
Wavelength Range340 to 850nm
Filters8-position filter wheel; filters installed: 405nm, 450nm, and 620nm
Linearity0–3 Abs, ± 2% at 405nm, 96-well plate
0–2.5 Abs, ± 2% at 405nm, 384-well plate
Resolution0.001 Abs
Accuracy± 1% (0–3 Abs) or ± 0.003 Abs, which ever is greater at 405nm
PrecisionCV ≤ 0.2% (0.3–3 Abs) at 405nm
Incubator TemperatureAmbient +4° to 50°C
ShakingLinear
Measurement Speed7 seconds, 96-well plate, fast mode; 13 seconds, 96-well plate, normal mode; 13 seconds, 384-well plate, fast mode; 34 seconds, 384-well plate, normal mode
Depth (Metric)40cm
Depth (English)15.7 in
Width (Metric)29cm
Width (English)11.4 in.
Height (Metric)22cm
Height (English)8.7 in.
CompatibilityRobot
Warranty1 Year
Detector TypePhotodetector
Light SourceQuartz-halogen lamp
Reading Options96 Well Plate; 384 Well Plate
Read-out Range0 to 6 Abs
Software TypeSkanIt Software
Product LineMultiskan™
InterfaceUser: On-board or PC control
Unit SizeEach
Showing 3 of 3
Catalog NumberSpecificationsUnit SizeDescriptionPlate TypePrice (USD)AvailabilityQuantity
51119000Full specifications
EachMultiskan FC96-well platesRequest A Quote--
DescriptionMultiskan FC
Plate Type96-well plates
Wavelength SelectionFilters
Wavelength Range340 to 850nm
Filters8-position filter wheel; filters installed: 405nm, 450nm, and 620nm
Linearity0–3 Abs, ± 2% at 405nm, 96-well plate
Resolution0.001 Abs
Accuracy± 1% (0–3 Abs) or ± 0.003 Abs, which ever is greater at 405nm
PrecisionCV ≤ 0.2% (0.3–3 Abs) at 405nm
Incubator TemperatureUp to 50°C
ShakingLinear
Measurement Speed7 seconds, 96-well plate, fast mode; 13 seconds, 96-well plate, normal mode
Depth (Metric)40cm
Depth (English)15.7 in.
Width (Metric)29cm
Width (English)11.4 in.
Height (Metric)22cm
Height (English)8.7 in.
CompatibilityRobot
Warranty1 Year
Detector TypePhotodetector
Light SourceQuartz-halogen lamp
Reading Options96 Well Plate; 384 Well Plate
Read-out Range0 to 6 Abs
Software TypeSkanIt Software
Product LineMultiskan™
InterfaceUser: On-board or PC control
Unit SizeEach
1410101Full specifications
EachAccessory - Lamp 6V/10W----
Price: 263.00
Your Price:
-
DescriptionAccessory - Lamp 6V/10W
Plate Type----
Light SourceLamp
Software TypeSkanIt Software
Unit SizeEach
51119100Full specifications
EachMultiskan FC with incubator96- and 384-well platesRequest A Quote--
DescriptionMultiskan FC with incubator
Plate Type96- and 384-well plates
Wavelength SelectionFilters
Wavelength Range340 to 850nm
Filters8-position filter wheel; filters installed: 405nm, 450nm, and 620nm
Linearity0–3 Abs, ± 2% at 405nm, 96-well plate
0–2.5 Abs, ± 2% at 405nm, 384-well plate
Resolution0.001 Abs
Accuracy± 1% (0–3 Abs) or ± 0.003 Abs, which ever is greater at 405nm
PrecisionCV ≤ 0.2% (0.3–3 Abs) at 405nm
Incubator TemperatureAmbient +4° to 50°C
ShakingLinear
Measurement Speed7 seconds, 96-well plate, fast mode; 13 seconds, 96-well plate, normal mode; 13 seconds, 384-well plate, fast mode; 34 seconds, 384-well plate, normal mode
Depth (Metric)40cm
Depth (English)15.7 in
Width (Metric)29cm
Width (English)11.4 in.
Height (Metric)22cm
Height (English)8.7 in.
CompatibilityRobot
Warranty1 Year
Detector TypePhotodetector
Light SourceQuartz-halogen lamp
Reading Options96 Well Plate; 384 Well Plate
Read-out Range0 to 6 Abs
Software TypeSkanIt Software
Product LineMultiskan™
InterfaceUser: On-board or PC control
Unit SizeEach
Showing 3 of 3
  • Proven performance and reliable day-to-day results through patented optical design and in-built self-diagnostics
  • A broad wavelength range of 340–850 nm for a wide variety of research and routine applications such as ELISA immunoassays, protein quantification, endotoxin, cytotoxicity and proliferation assays, enzyme assays and growth curves
  • Equipped with an eight-position filter wheel with three standard filters, 405 nm, 450 nm and 620 nm, preinstalled
  • A comprehensive range of easy-to install additional filters available for order
  • Fast and accurate measurement of both 96- and 384-well plates for various throughput requirements
  • Shaking and incubation up to 50°C for temperature critical assays
  • Ease of use through the large color screen and a variety of language versions
  • Visual and logical SkanIt software for comprehensive instrument control and data handling
  • Multiskan verification plate available for instrument performance verification
  • Robot compatibility for high-throughput environments
Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.