Catalog Number
840-210800
Unit Size
Each
dimProductLine
Type
Evolution 201 UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords
WarrantySpec
Price (USD)
Availability
-
Full specifications
Quantity
-
Accuracy (Photometric)0.5: ±0.004; 1: ±0.006; 2: ±0.010; Measured at 440nm using neutral density filters traceable to NIST
Certifications/ComplianceISO 9001:2008
ConnectionsUSB or RS-232
Detector TypeDual Silicon Photodiodes
DisplayNone
Operating SystemMicrosoft Windows 7, Windows 8
Photometric Accuracy Instrument1A: ±0.006A
2A: ±0.010A
Measured at 440 nm using calibrated neutra
TypeEvolution 201 UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords
Wavelength Accuracy±0.5 nm  (541.9, 546.1 nm mercury lines);
±0.8 nm (full range 190 to 1100 n
Wavelength Range190 to 1100nm
Baseline Flatness±0.0010A, 200-800nm, 1.0nm SBW, smoothing
Beam GeometryDouble-beam
Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
DescriptionCutting-edge instrumentation, intuitive and powerful software, and a wide range of accessories consistently deliver high quality results and improved productivity.
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in)
Drift<0.0005A/hr,
500 nm, 1.0 nm SBW, 1 hr warm-up
Electrical Requirements100-240V 50-60Hz, selected automatically, 150W maximum
Item DescriptionEvolution 201 UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords
LampXenon Flash Lamp, 3 year warranty (7 years typical lifetime)
Noise0A: <0.00015A;
1A:<0.00025A;
2A: <0.00080A;
260 nm, 1.0 nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Czerny-Turner Monochromator
Pathlength (Metric)Up to 100 mm cuvettes
Pharmacopoeia Compliance Testing
Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198 nm: KCI; ≤0.05%AT at 220 nm: Nal, Kl
Wavelength Accuracy: ±.5 nm 541.9, 546.1nm Hg emission lines, ±0.8 nm full range
Wavelength Repeatability: ≤0.05 nm, repetitive scanning of 546.1 nm Hg emission line
Photometric Display-0.3 to 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002A
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R). log (Abs) Abs*, Intensity
Scan Speed<1-6000nm/min, variable
Spectral Bandwidth1.0 nm
Wattage150W max.
Wavelength Repeatability≤0.05 nm (546.1 nm mercury line, SD of 10 measurements)
Wavelength Scan Speed<1 to 6000; variable
Weight (English)32 lb
Weight (Metric)14.4 kg
Unit SizeEach
Catalog Number
Unit Size
Each
dimProductLine
Type
Evolution 220 UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords
WarrantySpec
Price (USD)
Price: 5,000.00
Your Price:
Availability
-
Full specifications
Quantity
Detector TypeDual Silicon Photodiodes
DisplayNone
Operating SystemMicrosoft Windows 7, Windows 8
Photometric Accuracy Instrument1A: ±0.006A
2A: ±0.010A
Measured at 440 nm using calibrated neutra
TypeEvolution 220 UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords
Wavelength Accuracy±0.5 nm (541.9, 546.1 nm mercury lines), ±0.8 nm (full range 190 to 1100 nm)
Wavelength Range190 to 1100nm
Baseline Flatness±0.0010A, 200-800nm, 1.0nm SBW, smoothing
Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
DescriptionCutting-edge instrumentation, intuitive and powerful software, and a wide range of accessories consistently deliver high quality results and improved productivity
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in)
Drift<0.0005A/hr, 500nm, 1.0nm SBW, 1 hr warm-up
Electrical Requirements100-240V 50-60Hz, selected automatically, 150W maximum
Item DescriptionEvolution 220 UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords
KeypadSealed membrane
LampXenon Flash Lamp, 3 year warranty (7 years typical lifetime)
Noise0A: <0.00015A;
1A: <0.00025A;
2A: <0.00080A;
260 nm, 1nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Pharmacopoeia Compliance Testing(Guaranteed Performance Specifications)
Resolution (toluene in Hexane): ≥1.8A
Photometric Accuracy (60 mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198 nm: KCI; ≤ to 0.05 %AT at 220nm: Nal, Kl
Wavelength Accuracy: ±0.5 nm 541.9, 546.1 nm Hg emission lines, ±0.8 nm full range
Wavelength Repeatability: ≤0.05 nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 to 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002A
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Scan Speed<1-6000nm/min, variable
Spectral BandwidthVariable: 1.0nm; 2.0nm; AFBG Microcell optimized; AFBG Fiber optic optimized; AFBG Materials optimized
Wavelength Repeatability≤0.05nm (546.11nm mercury line, SD of 10 measurements)
Weight (English)32 lb
Weight (Metric)14.4 kg
Unit SizeEach
Catalog Number
Unit Size
Each
dimProductLine
Type
Evolution 201 Spectrophotometer plus Tablet Control Module (for US, CAN and JP only)
WarrantySpec
Price (USD)
Availability
-
Full specifications
Quantity
-
Accuracy (Photometric)0.5: ±0.004; 1: ±0.006; 2: ±0.010; Measured at 440nm using neutral density filters traceable to NIST
Certifications/ComplianceISO 9001:2008
ConnectionsUSB or RS-232
Detector TypeDual Silicon Photodiodes
DisplayNone
Operating SystemINSIGHT 2 Software is compatible with Windows™ 7 and Windows 8.1 Professional Editions
Photometric Accuracy Instrument1A: ±0.006A
2A: ±0.010A
Measured at 440nm using calibrated neutral
TypeEvolution 201 Spectrophotometer plus Tablet Control Module (for US, CAN and JP only)
Wavelength Accuracy±0.5nm  (541.9, 546.1nm mercury lines);
±0.8nm (full range 190 to 1100nm)
Wavelength Range190 to 1100nm
Baseline Flatness±0.0010A, 200-800nm, 1.0nm SBW, smoothing
Beam GeometryDouble-beam
Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
Depth (English)24.3 in.
Depth (Metric)62.2mm
DescriptionCutting-edge instrumentation, intuitive and powerful software, and a wide range of accessories consistently deliver high quality results and improved productivity.
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in)
Drift<0.0005A/hr,
500nm, 1.0nm SBW, 1 hr warm-up
Electrical Requirements100-240V 50-60Hz, selected automatically, 150W maximum
Item DescriptionEvolution 201 Tablet Control Module US, CAN, JP
KeypadSealed membrane
LampXenon Flash Lamp, 3 year warranty (7 years typical lifetime)
Noise0A: <0.00015A;
1A:<0.00025A;
2A: <0.00080A;
260nm, 1.0nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Czerny-Turner Monochromator
Pathlength (Metric)Up to 100mm cuvettes
Pharmacopoeia Compliance TestingResolution (Toluene in Hexane): ≥1.8A
Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, Kl
Wavelength Accuracy: ±.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range
Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 to 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002A
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R). log (Abs) Abs*, Intensity
Scan Speed<1-6000nm/min, variable
Spectral Bandwidth1.0nm
Wattage150W max.
Wavelength Repeatability≤0.05nm (546.1nm mercury line, SD of 10 measurements)
Wavelength Scan Speed<1 to 6000; variable
Weight (Metric)14.4kg
Unit SizeEach
Catalog Number
Unit Size
Each
dimProductLine
Type
Evolution 201 Spectrophotometer plus Tablet Control Module - International
WarrantySpec
Price (USD)
Availability
-
Full specifications
Quantity
-
Accuracy (Photometric)0.5: ±0.004; 1: ±0.006; 2: ±0.010; Measured at 440nm using neutral density filters traceable to NIST
Certifications/ComplianceISO 9001:2008
ConnectionsUSB or RS-232
Detector TypeDual Silicon Photodiodes
DisplayNone
Operating SystemINSIGHT 2 Software is compatible with Windows™ 7 and Windows 8.1 Professional Editions
Photometric Accuracy Instrument1A: ±0.006A
2A: ±0.010A
Measured at 440nm using calibrated neutral
TypeEvolution 201 Spectrophotometer plus Tablet Control Module - International
Wavelength Accuracy±0.5nm  (541.9, 546.1nm mercury lines);
±0.8nm (full range 190 to 1100nm)
Wavelength Range190 to 1100nm
Baseline Flatness±0.0010A, 200-800nm, 1.0nm SBW, smoothing
Beam GeometryDouble-beam
Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
Depth (English)24.3 in.
Depth (Metric)62.2mm
DescriptionCutting-edge instrumentation, intuitive and powerful software, and a wide range of accessories consistently deliver high quality results and improved productivity.
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in)
Drift<0.0005A/hr,
500nm, 1.0nm SBW, 1 hr warm-up
Electrical Requirements100-240V 50-60Hz, selected automatically, 150W maximum
Item DescriptionEvolution 201 Tablet Control Module Intl
KeypadSealed membrane
LampXenon Flash Lamp, 3 year warranty (7 years typical lifetime)
Noise0A: <0.00015A;
1A:<0.00025A;
2A: <0.00080A;
260nm, 1.0nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Czerny-Turner Monochromator
Pathlength (Metric)Up to 100mm cuvettes
Pharmacopoeia Compliance TestingResolution (Toluene in Hexane): ≥1.8A
Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, Kl
Wavelength Accuracy: ±.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range
Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 to 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002A
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R). log (Abs) Abs*, Intensity
Scan Speed<1-6000nm/min, variable
Spectral Bandwidth1.0nm
Wattage150W max.
Wavelength Repeatability≤0.05nm (546.1nm mercury line, SD of 10 measurements)
Wavelength Scan Speed<1 to 6000; variable
Weight (Metric)14.4kg
Unit SizeEach
Catalog Number
Unit Size
Each
dimProductLine
Type
Evolution 220 Spectrophotometer plus Tablet Control Module (for US, CAN and JP only)
WarrantySpec
Price (USD)
Availability
-
Full specifications
Quantity
-
Detector TypeDual Silicon Photodiodes
DisplayNone
Operating SystemMicrosoft Windows™ XP embedded. INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions.
Photometric Accuracy Instrument1A: ±0.006A
2A: ±0.010A
Measured at 440nm using calibrated neutral
TypeEvolution 220 Spectrophotometer plus Tablet Control Module (for US, CAN and JP only)
Wavelength Accuracy±0.5nm (541.9, 546.1nm mercury lines), ±0.8nm (full range 190 to 1100nm)
Wavelength Range190 to 1100nm
Baseline Flatness±0.0010A, 200-800nm, 1.0nm SBW, smoothing
Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
DescriptionCutting-edge instrumentation, intuitive and powerful software, and a wide range of accessories consistently deliver high quality results and improved productivity
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in)
Drift<0.0005A/hr, 500nm, 1.0nm SBW, 1 hr warm-up
Electrical Requirements100-240V 50-60Hz, selected automatically, 150W maximum
Item DescriptionEvolution 220 Tablet Control Module US, CAN, JP
KeypadSealed membrane
LampXenon Flash Lamp, 3 year warranty (7 years typical lifetime)
Noise0A: <0.00015A;
1A: <0.00025A;
2A: <0.00080A;
260nm, 1nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Pharmacopoeia Compliance Testing(Guaranteed Performance Specifications)
Resolution (toluene in Hexane): ≥1.8A
Photometric Accuracy (60 mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, Kl
Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range
Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 to 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002A
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Scan Speed<1-6000nm/min, variable
Spectral BandwidthVariable: 1.0nm; 2.0nm;  AFBG Microcell optimized; AFBG Fiber optic optimized; AFBG Materials optimized
Wavelength Repeatability≤0.05nm (546.11nm mercury line, SD of 10 measurements)
Weight (Metric)14.4kg
Unit SizeEach
Catalog Number
Unit Size
Each
dimProductLine
Type
Evolution 220 Spectrophotometer plus Tablet Control Module - International
WarrantySpec
Price (USD)
Availability
-
Full specifications
Quantity
-
Certifications/ComplianceCertificate of Analysis (COA), Certificate of Conformance (COC)
Detector TypeDual Silicon Photodiodes
DisplayNone
Operating SystemMicrosoft Windows™ XP embedded. INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions.
Photometric Accuracy Instrument1A: ±0.006A
2A: ±0.010A
Measured at 440nm using calibrated neutral
TypeEvolution 220 Spectrophotometer plus Tablet Control Module - International
Wavelength Accuracy±0.5nm (541.9, 546.1nm mercury lines), ±0.8nm (full range 190 to 1100nm)
Wavelength Range190 to 1100nm
ApplicationsSpectroscopy Elemental Isotope Analysis
Baseline Flatness±0.0010A, 200-800nm, 1.0nm SBW, smoothing
Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
DescriptionCutting-edge instrumentation, intuitive and powerful software, and a wide range of accessories consistently deliver high quality results and improved productivity
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in)
Drift<0.0005A/hr, 500nm, 1.0nm SBW, 1 hr warm-up
Electrical Requirements100-240V 50-60Hz, selected automatically, 150W maximum
Item DescriptionEvolution 220 Tablet Control Module Intl
KeypadSealed membrane
LampXenon Flash Lamp, 3 year warranty (7 years typical lifetime)
Noise0A: <0.00015A;
1A: <0.00025A;
2A: <0.00080A;
260nm, 1nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Pharmacopoeia Compliance Testing(Guaranteed Performance Specifications)
Resolution (toluene in Hexane): ≥1.8A
Photometric Accuracy (60 mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, Kl
Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range
Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 to 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002A
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Scan Speed<1-6000nm/min, variable
Spectral BandwidthVariable: 1.0nm; 2.0nm;  AFBG Microcell optimized; AFBG Fiber optic optimized; AFBG Materials optimized
Wavelength Repeatability≤0.05nm (546.11nm mercury line, SD of 10 measurements)
Weight (Metric)14.4kg
Unit SizeEach
Showing 6 of 6
Catalog NumberSpecificationsUnit SizedimProductLineTypeWarrantySpecPrice (USD)AvailabilityQuantity
840-210800Full specifications
EachEvolution 201 UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cordsRequest A Quote--
Accuracy (Photometric)0.5: ±0.004; 1: ±0.006; 2: ±0.010; Measured at 440nm using neutral density filters traceable to NIST
Certifications/ComplianceISO 9001:2008
ConnectionsUSB or RS-232
Detector TypeDual Silicon Photodiodes
DisplayNone
Operating SystemMicrosoft Windows 7, Windows 8
Photometric Accuracy Instrument1A: ±0.006A
2A: ±0.010A
Measured at 440 nm using calibrated neutra
TypeEvolution 201 UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords
Wavelength Accuracy±0.5 nm  (541.9, 546.1 nm mercury lines);
±0.8 nm (full range 190 to 1100 n
Wavelength Range190 to 1100nm
Baseline Flatness±0.0010A, 200-800nm, 1.0nm SBW, smoothing
Beam GeometryDouble-beam
Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
DescriptionCutting-edge instrumentation, intuitive and powerful software, and a wide range of accessories consistently deliver high quality results and improved productivity.
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in)
Drift<0.0005A/hr,
500 nm, 1.0 nm SBW, 1 hr warm-up
Electrical Requirements100-240V 50-60Hz, selected automatically, 150W maximum
Item DescriptionEvolution 201 UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords
LampXenon Flash Lamp, 3 year warranty (7 years typical lifetime)
Noise0A: <0.00015A;
1A:<0.00025A;
2A: <0.00080A;
260 nm, 1.0 nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Czerny-Turner Monochromator
Pathlength (Metric)Up to 100 mm cuvettes
Pharmacopoeia Compliance Testing
Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198 nm: KCI; ≤0.05%AT at 220 nm: Nal, Kl
Wavelength Accuracy: ±.5 nm 541.9, 546.1nm Hg emission lines, ±0.8 nm full range
Wavelength Repeatability: ≤0.05 nm, repetitive scanning of 546.1 nm Hg emission line
Photometric Display-0.3 to 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002A
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R). log (Abs) Abs*, Intensity
Scan Speed<1-6000nm/min, variable
Spectral Bandwidth1.0 nm
Wattage150W max.
Wavelength Repeatability≤0.05 nm (546.1 nm mercury line, SD of 10 measurements)
Wavelength Scan Speed<1 to 6000; variable
Weight (English)32 lb
Weight (Metric)14.4 kg
Unit SizeEach
840-210600Full specifications
EachEvolution 220 UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords
Price: 5,000.00
Your Price:
-
Detector TypeDual Silicon Photodiodes
DisplayNone
Operating SystemMicrosoft Windows 7, Windows 8
Photometric Accuracy Instrument1A: ±0.006A
2A: ±0.010A
Measured at 440 nm using calibrated neutra
TypeEvolution 220 UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords
Wavelength Accuracy±0.5 nm (541.9, 546.1 nm mercury lines), ±0.8 nm (full range 190 to 1100 nm)
Wavelength Range190 to 1100nm
Baseline Flatness±0.0010A, 200-800nm, 1.0nm SBW, smoothing
Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
DescriptionCutting-edge instrumentation, intuitive and powerful software, and a wide range of accessories consistently deliver high quality results and improved productivity
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in)
Drift<0.0005A/hr, 500nm, 1.0nm SBW, 1 hr warm-up
Electrical Requirements100-240V 50-60Hz, selected automatically, 150W maximum
Item DescriptionEvolution 220 UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords
KeypadSealed membrane
LampXenon Flash Lamp, 3 year warranty (7 years typical lifetime)
Noise0A: <0.00015A;
1A: <0.00025A;
2A: <0.00080A;
260 nm, 1nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Pharmacopoeia Compliance Testing(Guaranteed Performance Specifications)
Resolution (toluene in Hexane): ≥1.8A
Photometric Accuracy (60 mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198 nm: KCI; ≤ to 0.05 %AT at 220nm: Nal, Kl
Wavelength Accuracy: ±0.5 nm 541.9, 546.1 nm Hg emission lines, ±0.8 nm full range
Wavelength Repeatability: ≤0.05 nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 to 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002A
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Scan Speed<1-6000nm/min, variable
Spectral BandwidthVariable: 1.0nm; 2.0nm; AFBG Microcell optimized; AFBG Fiber optic optimized; AFBG Materials optimized
Wavelength Repeatability≤0.05nm (546.11nm mercury line, SD of 10 measurements)
Weight (English)32 lb
Weight (Metric)14.4 kg
Unit SizeEach
912A0883Full specifications
EachEvolution 201 Spectrophotometer plus Tablet Control Module (for US, CAN and JP only)Request A Quote--
Accuracy (Photometric)0.5: ±0.004; 1: ±0.006; 2: ±0.010; Measured at 440nm using neutral density filters traceable to NIST
Certifications/ComplianceISO 9001:2008
ConnectionsUSB or RS-232
Detector TypeDual Silicon Photodiodes
DisplayNone
Operating SystemINSIGHT 2 Software is compatible with Windows™ 7 and Windows 8.1 Professional Editions
Photometric Accuracy Instrument1A: ±0.006A
2A: ±0.010A
Measured at 440nm using calibrated neutral
TypeEvolution 201 Spectrophotometer plus Tablet Control Module (for US, CAN and JP only)
Wavelength Accuracy±0.5nm  (541.9, 546.1nm mercury lines);
±0.8nm (full range 190 to 1100nm)
Wavelength Range190 to 1100nm
Baseline Flatness±0.0010A, 200-800nm, 1.0nm SBW, smoothing
Beam GeometryDouble-beam
Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
Depth (English)24.3 in.
Depth (Metric)62.2mm
DescriptionCutting-edge instrumentation, intuitive and powerful software, and a wide range of accessories consistently deliver high quality results and improved productivity.
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in)
Drift<0.0005A/hr,
500nm, 1.0nm SBW, 1 hr warm-up
Electrical Requirements100-240V 50-60Hz, selected automatically, 150W maximum
Item DescriptionEvolution 201 Tablet Control Module US, CAN, JP
KeypadSealed membrane
LampXenon Flash Lamp, 3 year warranty (7 years typical lifetime)
Noise0A: <0.00015A;
1A:<0.00025A;
2A: <0.00080A;
260nm, 1.0nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Czerny-Turner Monochromator
Pathlength (Metric)Up to 100mm cuvettes
Pharmacopoeia Compliance TestingResolution (Toluene in Hexane): ≥1.8A
Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, Kl
Wavelength Accuracy: ±.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range
Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 to 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002A
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R). log (Abs) Abs*, Intensity
Scan Speed<1-6000nm/min, variable
Spectral Bandwidth1.0nm
Wattage150W max.
Wavelength Repeatability≤0.05nm (546.1nm mercury line, SD of 10 measurements)
Wavelength Scan Speed<1 to 6000; variable
Weight (Metric)14.4kg
Unit SizeEach
912A0890Full specifications
EachEvolution 201 Spectrophotometer plus Tablet Control Module - InternationalRequest A Quote--
Accuracy (Photometric)0.5: ±0.004; 1: ±0.006; 2: ±0.010; Measured at 440nm using neutral density filters traceable to NIST
Certifications/ComplianceISO 9001:2008
ConnectionsUSB or RS-232
Detector TypeDual Silicon Photodiodes
DisplayNone
Operating SystemINSIGHT 2 Software is compatible with Windows™ 7 and Windows 8.1 Professional Editions
Photometric Accuracy Instrument1A: ±0.006A
2A: ±0.010A
Measured at 440nm using calibrated neutral
TypeEvolution 201 Spectrophotometer plus Tablet Control Module - International
Wavelength Accuracy±0.5nm  (541.9, 546.1nm mercury lines);
±0.8nm (full range 190 to 1100nm)
Wavelength Range190 to 1100nm
Baseline Flatness±0.0010A, 200-800nm, 1.0nm SBW, smoothing
Beam GeometryDouble-beam
Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
Depth (English)24.3 in.
Depth (Metric)62.2mm
DescriptionCutting-edge instrumentation, intuitive and powerful software, and a wide range of accessories consistently deliver high quality results and improved productivity.
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in)
Drift<0.0005A/hr,
500nm, 1.0nm SBW, 1 hr warm-up
Electrical Requirements100-240V 50-60Hz, selected automatically, 150W maximum
Item DescriptionEvolution 201 Tablet Control Module Intl
KeypadSealed membrane
LampXenon Flash Lamp, 3 year warranty (7 years typical lifetime)
Noise0A: <0.00015A;
1A:<0.00025A;
2A: <0.00080A;
260nm, 1.0nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Czerny-Turner Monochromator
Pathlength (Metric)Up to 100mm cuvettes
Pharmacopoeia Compliance TestingResolution (Toluene in Hexane): ≥1.8A
Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, Kl
Wavelength Accuracy: ±.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range
Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 to 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002A
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R). log (Abs) Abs*, Intensity
Scan Speed<1-6000nm/min, variable
Spectral Bandwidth1.0nm
Wattage150W max.
Wavelength Repeatability≤0.05nm (546.1nm mercury line, SD of 10 measurements)
Wavelength Scan Speed<1 to 6000; variable
Weight (Metric)14.4kg
Unit SizeEach
912A0884Full specifications
EachEvolution 220 Spectrophotometer plus Tablet Control Module (for US, CAN and JP only)Request A Quote--
Detector TypeDual Silicon Photodiodes
DisplayNone
Operating SystemMicrosoft Windows™ XP embedded. INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions.
Photometric Accuracy Instrument1A: ±0.006A
2A: ±0.010A
Measured at 440nm using calibrated neutral
TypeEvolution 220 Spectrophotometer plus Tablet Control Module (for US, CAN and JP only)
Wavelength Accuracy±0.5nm (541.9, 546.1nm mercury lines), ±0.8nm (full range 190 to 1100nm)
Wavelength Range190 to 1100nm
Baseline Flatness±0.0010A, 200-800nm, 1.0nm SBW, smoothing
Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
DescriptionCutting-edge instrumentation, intuitive and powerful software, and a wide range of accessories consistently deliver high quality results and improved productivity
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in)
Drift<0.0005A/hr, 500nm, 1.0nm SBW, 1 hr warm-up
Electrical Requirements100-240V 50-60Hz, selected automatically, 150W maximum
Item DescriptionEvolution 220 Tablet Control Module US, CAN, JP
KeypadSealed membrane
LampXenon Flash Lamp, 3 year warranty (7 years typical lifetime)
Noise0A: <0.00015A;
1A: <0.00025A;
2A: <0.00080A;
260nm, 1nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Pharmacopoeia Compliance Testing(Guaranteed Performance Specifications)
Resolution (toluene in Hexane): ≥1.8A
Photometric Accuracy (60 mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, Kl
Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range
Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 to 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002A
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Scan Speed<1-6000nm/min, variable
Spectral BandwidthVariable: 1.0nm; 2.0nm;  AFBG Microcell optimized; AFBG Fiber optic optimized; AFBG Materials optimized
Wavelength Repeatability≤0.05nm (546.11nm mercury line, SD of 10 measurements)
Weight (Metric)14.4kg
Unit SizeEach
912A0889Full specifications
EachEvolution 220 Spectrophotometer plus Tablet Control Module - InternationalRequest A Quote--
Certifications/ComplianceCertificate of Analysis (COA), Certificate of Conformance (COC)
Detector TypeDual Silicon Photodiodes
DisplayNone
Operating SystemMicrosoft Windows™ XP embedded. INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions.
Photometric Accuracy Instrument1A: ±0.006A
2A: ±0.010A
Measured at 440nm using calibrated neutral
TypeEvolution 220 Spectrophotometer plus Tablet Control Module - International
Wavelength Accuracy±0.5nm (541.9, 546.1nm mercury lines), ±0.8nm (full range 190 to 1100nm)
Wavelength Range190 to 1100nm
ApplicationsSpectroscopy Elemental Isotope Analysis
Baseline Flatness±0.0010A, 200-800nm, 1.0nm SBW, smoothing
Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
DescriptionCutting-edge instrumentation, intuitive and powerful software, and a wide range of accessories consistently deliver high quality results and improved productivity
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in)
Drift<0.0005A/hr, 500nm, 1.0nm SBW, 1 hr warm-up
Electrical Requirements100-240V 50-60Hz, selected automatically, 150W maximum
Item DescriptionEvolution 220 Tablet Control Module Intl
KeypadSealed membrane
LampXenon Flash Lamp, 3 year warranty (7 years typical lifetime)
Noise0A: <0.00015A;
1A: <0.00025A;
2A: <0.00080A;
260nm, 1nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Pharmacopoeia Compliance Testing(Guaranteed Performance Specifications)
Resolution (toluene in Hexane): ≥1.8A
Photometric Accuracy (60 mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, Kl
Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range
Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 to 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002A
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Scan Speed<1-6000nm/min, variable
Spectral BandwidthVariable: 1.0nm; 2.0nm;  AFBG Microcell optimized; AFBG Fiber optic optimized; AFBG Materials optimized
Wavelength Repeatability≤0.05nm (546.11nm mercury line, SD of 10 measurements)
Weight (Metric)14.4kg
Unit SizeEach
Showing 6 of 6
New sales of this model have been discontinued. Please see the newest models: the Evolution One/One Plus Spectrophotometers.