Thermo Scientific™

Evolution™ 260 Bio UV-Visible Spectrophotometer

Catalog number: 912A0888
Thermo Scientific™

Evolution™ 260 Bio UV-Visible Spectrophotometer

Catalog number: 912A0888

New sales of this model have been discontinued. Please see the newest models: the Evolution Pro Spectrophotometers.

 
Catalog Number
912A0888
Unit Size
Each
Description
Evolution 260 Bio Spectrophotometer plus Tablet Control Module - International
Price (USD)
Availability
-
Full specifications
Quantity
-
Accuracy (Photometric)1A: ±0.006A
2A: ±0.010A
Measured at 440nm using calibrated neutral
Certifications/ComplianceISO 9001:2008
Detector TypeDual Silicon Photodiodes
DisplayTouchscreen LCD panel; 800 x 480; 17.8 cm (7 in. diagonal)
Operating SystemMicrosoft Windows™ XP embedded
INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions and can be installed on a computer attached to the instrument
Photometric Accuracy Instrument1A: ±0.006A
2A: ±0.010A
Measured at 440nm using calibrated neutral
TypeEvolution 260 Bio Spectrophotometer plus Tablet Control Module - International
Wavelength Accuracy±0.5nm (541.9, 546.1nm mercury lines)
±0.8nm (full range 190-1100nm)
Wavelength Range190 - 1,100nm
ApplicationsSpectroscopy Elemental Isotope Analysis
Baseline Flatness±0.0010A, 200-800nm, 1.0nm SBW, smoothing
Beam GeometryDouble-beam with Application Focused Beam Geometry
Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
DescriptionEvolution 260 Bio Spectrophotometer plus Tablet Control Module - International
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in)
Drift<0.0005 A/hr, 500 nm, 1.0nm SBW, 1 hr warm-up
Electrical Requirements100-240 V 50-60 Hz selected automatically, 150W maximum
Item DescriptionEvolution 260 Bio Spectrophotometer plus Tablet Control Module - International
KeypadSealed membrane
LampXenon Flash Lamp, 3-year warranty (7 years typical lifetime)
Noise0A: <0.00015A
1A: <0.00025A
2A: <0.00080A
260nm, 1.0nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Pharmacopoeia Compliance Testing(Guaranteed Performance Specifications)
Resolution (toluene in Hexane): ≥1.8A
Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, KI
Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range
Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 - 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002A
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Scan Speed<1-6000nm/min, variable
Spectral BandwidthVariable: 1.0nm; 2.0nm; AFBG microcell optimized; AFBG fiber optic optimized; AFBG materials optimized
Wavelength Scan Speed<1 to 6,000 nm/min; variable
Weight (Metric)14.4 kg
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Evolution 260 Bio UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords
Price (USD)
Availability
-
Full specifications
Quantity
-
Accuracy (Photometric)1A: ±0.006A 2A: ±0.010A Measured at 440nm using calibrated neutral density filters tra
Certifications/ComplianceISO 9001:2008
Detector TypeDual Silicon Photodiodes
Operating SystemMicrosoft Windows 7, Windows 8
Photometric Accuracy Instrument1A: ±0.006A 2A: ±0.010A Measured at 440nm using calibrated neutral density filters tra
TypeEvolution 260 Bio UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords
Wavelength Accuracy±0.5nm (541.9, 546.1nm mercury lines) ±0.8nm (full range 190-1100nm)
Wavelength Range190 to 1100 nm
Baseline Flatness±0.0010A, 200-800nm, 1.0nm SBW, smoothing
Beam GeometryDouble-beam with Application Focused Beam Geometry
Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
DescriptionEvolution 260 Bio UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in)
Drift<0.0005 A/hr, 500 nm, 1.0nm SBW, 1 hr warm-up
Electrical Requirements100-240 V 50-60 Hz selected automatically, 150W maximum
LampXenon Flash Lamp, 3-year warranty (7 years typical lifetime)
Noise0A: <0.00015A
1A: <0.00025A
2A: <0.00080A
260nm, 1.0nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Pharmacopoeia Compliance Testing(Guaranteed Performance Specifications) Resolution (toluene in Hexane): ≥1.8A Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, KI Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 - 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002A
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Scan Speed<1-6000nm/min, variable
Spectral BandwidthVariable: 1.0nm; 2.0nm; AFBG microcell optimized; AFBG fiber optic optimized; AFBG materials optimized
Wavelength Scan Speed<1 to 6000 nm/min; variable
Weight (English)32 lb
Weight (Metric)14.4 kg
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Evolution 260 Bio Spectrophotometer plus Tablet Control Module - US CAN JP
Price (USD)
Price: 10,850.00
Your Price:
Availability
-
Full specifications
Quantity
Accuracy (Photometric)1A: ±0.006A
2A: ±0.010A
Measured at 440nm using calibrated neutral
Certifications/ComplianceISO 9001:2008
Detector TypeDual Silicon Photodiodes
DisplayTouchscreen LCD panel; 800 x 480; 17.8 cm (7 in. diagonal)
Operating SystemMicrosoft Windows™ XP embedded
INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions and can be installed on a computer attached to the instrument
Photometric Accuracy Instrument1A: ±0.006A
2A: ±0.010A
Measured at 440nm using calibrated neutral
TypeEvolution 260 Bio Spectrophotometer plus Tablet Control Module - US CAN JP
Wavelength Accuracy±0.5nm (541.9, 546.1nm mercury lines)
±0.8nm (full range 190-1100nm)
Wavelength Range190 - 1,100nm
Baseline Flatness±0.0010A, 200-800nm, 1.0nm SBW, smoothing
Beam GeometryDouble-beam with Application Focused Beam Geometry
Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
DescriptionEvolution 260 Bio Spectrophotometer plus Tablet Control Module - US CAN JP
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in)
Drift<0.0005 A/hr, 500 nm, 1.0nm SBW, 1 hr warm-up
Electrical Requirements100-240 V 50-60 Hz selected automatically, 150W maximum
Item DescriptionEvolution 260 Bio Spectrophotometer plus Tablet Control Module - US CAN JP
KeypadSealed membrane
LampXenon Flash Lamp, 3-year warranty (7 years typical lifetime)
Noise0A: <0.00015A
1A: <0.00025A
2A: <0.00080A
260nm, 1.0nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Pharmacopoeia Compliance Testing(Guaranteed Performance Specifications)
Resolution (toluene in Hexane): ≥1.8A
Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, KI
Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range
Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 - 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002A
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Scan Speed<1-6000nm/min, variable
Spectral BandwidthVariable: 1.0nm; 2.0nm; AFBG microcell optimized; AFBG fiber optic optimized; AFBG materials optimized
Wavelength Scan Speed<1 to 6,000 nm/min; variable
Weight (Metric)14.4 kg
Unit SizeEach
Showing 3 of 3
Catalog NumberSpecificationsUnit SizeDescriptionPrice (USD)AvailabilityQuantity
912A0888Full specifications
EachEvolution 260 Bio Spectrophotometer plus Tablet Control Module - InternationalRequest A Quote--
Accuracy (Photometric)1A: ±0.006A
2A: ±0.010A
Measured at 440nm using calibrated neutral
Certifications/ComplianceISO 9001:2008
Detector TypeDual Silicon Photodiodes
DisplayTouchscreen LCD panel; 800 x 480; 17.8 cm (7 in. diagonal)
Operating SystemMicrosoft Windows™ XP embedded
INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions and can be installed on a computer attached to the instrument
Photometric Accuracy Instrument1A: ±0.006A
2A: ±0.010A
Measured at 440nm using calibrated neutral
TypeEvolution 260 Bio Spectrophotometer plus Tablet Control Module - International
Wavelength Accuracy±0.5nm (541.9, 546.1nm mercury lines)
±0.8nm (full range 190-1100nm)
Wavelength Range190 - 1,100nm
ApplicationsSpectroscopy Elemental Isotope Analysis
Baseline Flatness±0.0010A, 200-800nm, 1.0nm SBW, smoothing
Beam GeometryDouble-beam with Application Focused Beam Geometry
Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
DescriptionEvolution 260 Bio Spectrophotometer plus Tablet Control Module - International
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in)
Drift<0.0005 A/hr, 500 nm, 1.0nm SBW, 1 hr warm-up
Electrical Requirements100-240 V 50-60 Hz selected automatically, 150W maximum
Item DescriptionEvolution 260 Bio Spectrophotometer plus Tablet Control Module - International
KeypadSealed membrane
LampXenon Flash Lamp, 3-year warranty (7 years typical lifetime)
Noise0A: <0.00015A
1A: <0.00025A
2A: <0.00080A
260nm, 1.0nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Pharmacopoeia Compliance Testing(Guaranteed Performance Specifications)
Resolution (toluene in Hexane): ≥1.8A
Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, KI
Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range
Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 - 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002A
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Scan Speed<1-6000nm/min, variable
Spectral BandwidthVariable: 1.0nm; 2.0nm; AFBG microcell optimized; AFBG fiber optic optimized; AFBG materials optimized
Wavelength Scan Speed<1 to 6,000 nm/min; variable
Weight (Metric)14.4 kg
Unit SizeEach
840-211000Full specifications
EachEvolution 260 Bio UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cordsRequest A Quote--
Accuracy (Photometric)1A: ±0.006A 2A: ±0.010A Measured at 440nm using calibrated neutral density filters tra
Certifications/ComplianceISO 9001:2008
Detector TypeDual Silicon Photodiodes
Operating SystemMicrosoft Windows 7, Windows 8
Photometric Accuracy Instrument1A: ±0.006A 2A: ±0.010A Measured at 440nm using calibrated neutral density filters tra
TypeEvolution 260 Bio UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords
Wavelength Accuracy±0.5nm (541.9, 546.1nm mercury lines) ±0.8nm (full range 190-1100nm)
Wavelength Range190 to 1100 nm
Baseline Flatness±0.0010A, 200-800nm, 1.0nm SBW, smoothing
Beam GeometryDouble-beam with Application Focused Beam Geometry
Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
DescriptionEvolution 260 Bio UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in)
Drift<0.0005 A/hr, 500 nm, 1.0nm SBW, 1 hr warm-up
Electrical Requirements100-240 V 50-60 Hz selected automatically, 150W maximum
LampXenon Flash Lamp, 3-year warranty (7 years typical lifetime)
Noise0A: <0.00015A
1A: <0.00025A
2A: <0.00080A
260nm, 1.0nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Pharmacopoeia Compliance Testing(Guaranteed Performance Specifications) Resolution (toluene in Hexane): ≥1.8A Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, KI Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 - 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002A
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Scan Speed<1-6000nm/min, variable
Spectral BandwidthVariable: 1.0nm; 2.0nm; AFBG microcell optimized; AFBG fiber optic optimized; AFBG materials optimized
Wavelength Scan Speed<1 to 6000 nm/min; variable
Weight (English)32 lb
Weight (Metric)14.4 kg
Unit SizeEach
912A0885Full specifications
EachEvolution 260 Bio Spectrophotometer plus Tablet Control Module - US CAN JP
Price: 10,850.00
Your Price:
-
Accuracy (Photometric)1A: ±0.006A
2A: ±0.010A
Measured at 440nm using calibrated neutral
Certifications/ComplianceISO 9001:2008
Detector TypeDual Silicon Photodiodes
DisplayTouchscreen LCD panel; 800 x 480; 17.8 cm (7 in. diagonal)
Operating SystemMicrosoft Windows™ XP embedded
INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions and can be installed on a computer attached to the instrument
Photometric Accuracy Instrument1A: ±0.006A
2A: ±0.010A
Measured at 440nm using calibrated neutral
TypeEvolution 260 Bio Spectrophotometer plus Tablet Control Module - US CAN JP
Wavelength Accuracy±0.5nm (541.9, 546.1nm mercury lines)
±0.8nm (full range 190-1100nm)
Wavelength Range190 - 1,100nm
Baseline Flatness±0.0010A, 200-800nm, 1.0nm SBW, smoothing
Beam GeometryDouble-beam with Application Focused Beam Geometry
Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
DescriptionEvolution 260 Bio Spectrophotometer plus Tablet Control Module - US CAN JP
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in)
Drift<0.0005 A/hr, 500 nm, 1.0nm SBW, 1 hr warm-up
Electrical Requirements100-240 V 50-60 Hz selected automatically, 150W maximum
Item DescriptionEvolution 260 Bio Spectrophotometer plus Tablet Control Module - US CAN JP
KeypadSealed membrane
LampXenon Flash Lamp, 3-year warranty (7 years typical lifetime)
Noise0A: <0.00015A
1A: <0.00025A
2A: <0.00080A
260nm, 1.0nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Pharmacopoeia Compliance Testing(Guaranteed Performance Specifications)
Resolution (toluene in Hexane): ≥1.8A
Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, KI
Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range
Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 - 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002A
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Scan Speed<1-6000nm/min, variable
Spectral BandwidthVariable: 1.0nm; 2.0nm; AFBG microcell optimized; AFBG fiber optic optimized; AFBG materials optimized
Wavelength Scan Speed<1 to 6,000 nm/min; variable
Weight (Metric)14.4 kg
Unit SizeEach
Showing 3 of 3

New sales of this model have been discontinued. Please see the newest models: the Evolution Pro Spectrophotometers.