Thermo Scientific™

ISQ™ Series Single Quadrupole GC-MS Systems

Catalog number: IQLAAAGAAJFALOMAYE
Thermo Scientific™

ISQ™ Series Single Quadrupole GC-MS Systems

Catalog number: IQLAAAGAAJFALOMAYE
Choose Thermo Scientific™ ISQ™ Series Quadrupole GC-MS Systems for time-proven performance and productivity. The ISQ GC-MS Series features a new source design ideal for continuous high-throughput operation. The vacuum interlock enables source removal without venting the system, enabling nonstop productivity in your laboratory.

The ISQ Series consists of two models: the ISQ QD GC-MS system with quality design capabilities, and the ISQ LT GC-MS system with leading technology capabilities. Please visit the corresponding product pages for model-specific information.

 
Catalog Number
IQLAAAGAAJFALOMAYE
Unit Size
Each
Source Type
ExtractaBrite EI Source, with Repeller, Source Lenses, RF Lens and Dual Filaments in All Ionization Modes
Price (USD)
Full specifications
Mass Range1.2 to 1100 U with Unit Mass Resolution
TypeSingle Quadrupole GC-MS
DetectorsDynaMax XR
EI Full Scan Installation Specification1 µL of 1 pg/µL Octafluoronaphthalene (OFN) Will Produce The Following Minimum Signal to Noise for m/z 272 When Scanning From 50 to 300 U:600:1 Using Helium as Carrier Gas
Electron EnergyAdjustable From 0 to 150 eV
Emission CurrentUp to 350 µA
Mass FilterDual-Stage Mass Filter with Off-Axis Ion Guide and Solid, Homogeneous Non-Coated Quadrupole Rods
ModesStandard: Electron Ionization (EI), with Full Scan, SIM, and Sequential Full Scan/SIM; Optional: Chemical Ionization, Including PCI, NCI, PPINICI and EI/CI Combination
Negative Chemical Ionization Installation Spec2 µL of 100 fg/µL of OFN Will Produce The Following Minimum Signal to Noise for m/z 272 When Scanning From 50 to 300 U Using Methane Reagent Gas: 600:1 Using Helium as Carrier Gas
Pumping SystemsStandard Capacity (>60 L/s) or High-Capacity (>230 L/s), or Extended Capacity (300 L/s) Turbomolecular Pump with 3.3 m3/h Mechanical Pump; Optional Oil-Free Scroll Pump
Reagent GasSoftware-Switchable Dual Reagent Gas with Digital Flow Control
Scanning CapabilitiesScan Rate: Up to 20,000 U/Sec; Scan Cycles: 97 Scans/Sec to Disc When Scanning Across 125 U
Source TypeExtractaBrite EI Source, with Repeller, Source Lenses, RF Lens and Dual Filaments in All Ionization Modes
Vacuum Probe InterlockVacuum Probe Interlock to Remove Entire Source or Change Ionization Modes Without Venting
Item DescriptionISQ Single Quadrupole Mass Spectrometer
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizeSource TypePrice (USD)
IQLAAAGAAJFALOMAYEFull specifications
EachExtractaBrite EI Source, with Repeller, Source Lenses, RF Lens and Dual Filaments in All Ionization ModesRequest A Quote
Mass Range1.2 to 1100 U with Unit Mass Resolution
TypeSingle Quadrupole GC-MS
DetectorsDynaMax XR
EI Full Scan Installation Specification1 µL of 1 pg/µL Octafluoronaphthalene (OFN) Will Produce The Following Minimum Signal to Noise for m/z 272 When Scanning From 50 to 300 U:600:1 Using Helium as Carrier Gas
Electron EnergyAdjustable From 0 to 150 eV
Emission CurrentUp to 350 µA
Mass FilterDual-Stage Mass Filter with Off-Axis Ion Guide and Solid, Homogeneous Non-Coated Quadrupole Rods
ModesStandard: Electron Ionization (EI), with Full Scan, SIM, and Sequential Full Scan/SIM; Optional: Chemical Ionization, Including PCI, NCI, PPINICI and EI/CI Combination
Negative Chemical Ionization Installation Spec2 µL of 100 fg/µL of OFN Will Produce The Following Minimum Signal to Noise for m/z 272 When Scanning From 50 to 300 U Using Methane Reagent Gas: 600:1 Using Helium as Carrier Gas
Pumping SystemsStandard Capacity (>60 L/s) or High-Capacity (>230 L/s), or Extended Capacity (300 L/s) Turbomolecular Pump with 3.3 m3/h Mechanical Pump; Optional Oil-Free Scroll Pump
Reagent GasSoftware-Switchable Dual Reagent Gas with Digital Flow Control
Scanning CapabilitiesScan Rate: Up to 20,000 U/Sec; Scan Cycles: 97 Scans/Sec to Disc When Scanning Across 125 U
Source TypeExtractaBrite EI Source, with Repeller, Source Lenses, RF Lens and Dual Filaments in All Ionization Modes
Vacuum Probe InterlockVacuum Probe Interlock to Remove Entire Source or Change Ionization Modes Without Venting
Item DescriptionISQ Single Quadrupole Mass Spectrometer
Unit SizeEach
Showing 1 of 1
A Robust, Reliable and Affordable Solution for Nonstop Productivity
  • Extended dynamic range detection system
  • Thermo Scientific™ ExtractaBrite™ source for analytical robustness
  • Mass range from 1.2 to 1100 u
  • S-Shaped Ion Guide for noise reduction
  • Data acquisition rates to match fast chromatography
  • Full Scan/SIM simultaneous within one injection for qualitative and quantitative analysis
  • Intelligent dual filament control for reliable operation
Flexible Configuration Options to Meet the Analytical Needs of Your Laboratory
  • Choice of gas chromatographs to match GC performance
  • Range of Instant Connect modular injection module options, all with available large-volume and back-flush capabilities for enhanced sensitivity and reduced sample preparation needs
  • Liquid and headspace autosampler options
  • Compatible with additional sample introduction techniques, such as thermal desorption, purge and trap, and solid phase microextraction
Compatible with a Wide Range of Software
  • Thermo Scientific™ Xcalibur™ data acquisition and processing software for research environments
  • Thermo Scientific™ TraceFinder™ data acquisition and processing software for general quantitation, environmental and food safety, clinical research, and forensic toxicology analyses
  • Thermo Scientific™ Dionex™ Chromeleon™ Simply Intelligent™ data acquisition and processing software for QA/QC and pharmaceutical applications.
Environmental Note:

U.S. EPA target tune capability using TraceFinder EFS.

Compatible With:

TRACE 1300 GC, TRACE 1310 GC, Thermo Scientific™ TriPlus™ RSH Autosampler, TriPlus 300 HS Autosampler

Warranty and Service Offering:

1 year