Thermo Scientific™

UltraDry EDS Detector

Catalog number: IQLAADGABKFABSMANG
Thermo Scientific™

UltraDry EDS Detector

Catalog number: IQLAADGABKFABSMANG

Develop faster, more accurate interpretation of X-rays for industries such as metals and mining, advanced materials and semiconductors with the Thermo Scientific™ UltraDry EDS Detector, which provides superior resolution at incredibly high collection rates for the Thermo Scientific™ Pathfinder™ X-ray Microanalysis Software.

 
Catalog Number
IQLAADGABKFABSMANG
Unit Size
Each
Active Area
Up to 100 mm²
Integrated Operation
EDS, WDS, and EBSD operation and analysis in a fully unified software platform.
Phase Mapping
The Pathfinder X-ray Microanalysis Software allows you to identify phases during the acquisition.
Price (USD)
Full specifications
Integrated OperationEDS, WDS, and EBSD operation and analysis in a fully unified software platform.
Operating Environment35°C
OptionsMotorized slide
Peak Shift±5eV peak shift (±3eV typical between 1% and 60% deadtime) from minimum to maximum count rate at a given analyzer time constant
Phase MappingThe Pathfinder X-ray Microanalysis Software allows you to identify phases during the acquisition.
Resolution±5 eV resolution change (±3eV typical between 1% and 60% deadtime) from minimum to maximum count rate at a given analyzer time constant
STD Distance50 mm
Active AreaUp to 100 mm²
Third Party CommunicationIntegration with third party applications such as
Analysis AutomationExpands the capability of all applications, and improves laboratory productivity by collecting X-ray microanalysis data from multiple locations in unattended operation
TOA35°
FWHM Measured5.89 keV (Mn-Ka) with 10,000 counts per second
Input Counts>1,000,000
Chemical TypingChemical Typing software classifies particles by matching their quantitative chemical composition to a database.
Feature SizingFeature Sizing software collects the morphological and chemical characteristics of infrequently occurring particles in large area samples.
DescriptionUltraDry EDS Detector
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizeActive AreaIntegrated OperationPhase MappingPrice (USD)
IQLAADGABKFABSMANGFull specifications
EachUp to 100 mm²EDS, WDS, and EBSD operation and analysis in a fully unified software platform.The Pathfinder X-ray Microanalysis Software allows you to identify phases during the acquisition.Request A Quote
Integrated OperationEDS, WDS, and EBSD operation and analysis in a fully unified software platform.
Operating Environment35°C
OptionsMotorized slide
Peak Shift±5eV peak shift (±3eV typical between 1% and 60% deadtime) from minimum to maximum count rate at a given analyzer time constant
Phase MappingThe Pathfinder X-ray Microanalysis Software allows you to identify phases during the acquisition.
Resolution±5 eV resolution change (±3eV typical between 1% and 60% deadtime) from minimum to maximum count rate at a given analyzer time constant
STD Distance50 mm
Active AreaUp to 100 mm²
Third Party CommunicationIntegration with third party applications such as
Analysis AutomationExpands the capability of all applications, and improves laboratory productivity by collecting X-ray microanalysis data from multiple locations in unattended operation
TOA35°
FWHM Measured5.89 keV (Mn-Ka) with 10,000 counts per second
Input Counts>1,000,000
Chemical TypingChemical Typing software classifies particles by matching their quantitative chemical composition to a database.
Feature SizingFeature Sizing software collects the morphological and chemical characteristics of infrequently occurring particles in large area samples.
DescriptionUltraDry EDS Detector
Unit SizeEach
Showing 1 of 1

The UltraDry EDS Detector Features:

  • Extraordinary operating space to enable superior performance with advanced field-effect transistor (FET) integration and a proprietary preamplifier stage 
  • A smaller, integrated FET to virtually eliminate electronic noise
  • Minimized dead time and maximized resolution to effectively handle pulse pile-up and sum peaks
  • Eliminated external or liquid nitrogen cooling with while maintaining extremely high data collection rate 
  • Consistent data collection rates across the widest range of distances — absolutely critical to dual EDS and EBSD acquisition — with unique slotted collimator design
  • One of the greatest solid angle of collection available for detectors on the market today with crystal active area range (10mm2, 30mm2, 60mm2, 100mm2) and small packaging envelope