Thermo Scientific™

Exactive™ Plus Orbitrap Mass Spectrometer

Catalog number: IQLAAEGAAPFALGMBCA
Thermo Scientific™

Exactive™ Plus Orbitrap Mass Spectrometer

Catalog number: IQLAAEGAAPFALGMBCA

Screen, identify and quantify compounds in complex samples rapidly and with confidence using the Thermo Scientific™ Exactive™ Plus Orbitrap Mass Spectrometer. This benchtop LC-MS system delivers high-resolution, accurate-mass (HR/AM) data and fast full-scan capabilities to increase your sample throughput and confidence in results. Easy-to-use and cost effective to operate, it is the ideal instrument for analytical laboratories performing food safety or environmental screening, clinical research, forensic toxicology, DMPK, metabolomics and biopharma (intact protein analysis) applications.

 
Catalog Number
IQLAAEGAAPFALGMBCA
Unit Size
Each
Description
Exactive Plus Orbitrap mass spectrometer
Price (USD)
Full specifications
Mass Range50 to 6000 m/z
TypeOrbitrap LC-MS
Dynamic Range>5000 for a Single Positive/Negative Scan
Mass Accuracy<1ppm using internal calibration, <3ppm with external calibration
Polarity SwitchingOne Full Cycle in <1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 35,000))
SensitivityA Flow Injection of 500 fg of Buspirone Giving a S/N of Better Than 10:1 for The Selected Mass Chromatogram of The [M+H]+ Ion
Resolution140,000 at m/z 200 at a scan rate of 1.5Hz, minimum resolution 17,500 at m/z 200 at a scan rate of 12Hz
DescriptionExactive Plus Orbitrap mass spectrometer
Scan RatesFull, All-Ion Fragmentation (AIF) by HCD, Data-Dependent AIF
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizeDescriptionPrice (USD)
IQLAAEGAAPFALGMBCAFull specifications
EachExactive Plus Orbitrap mass spectrometerRequest A Quote
Mass Range50 to 6000 m/z
TypeOrbitrap LC-MS
Dynamic Range>5000 for a Single Positive/Negative Scan
Mass Accuracy<1ppm using internal calibration, <3ppm with external calibration
Polarity SwitchingOne Full Cycle in <1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 35,000))
SensitivityA Flow Injection of 500 fg of Buspirone Giving a S/N of Better Than 10:1 for The Selected Mass Chromatogram of The [M+H]+ Ion
Resolution140,000 at m/z 200 at a scan rate of 1.5Hz, minimum resolution 17,500 at m/z 200 at a scan rate of 12Hz
DescriptionExactive Plus Orbitrap mass spectrometer
Scan RatesFull, All-Ion Fragmentation (AIF) by HCD, Data-Dependent AIF
Unit SizeEach
Showing 1 of 1
Quick, High-Confidence Results
  • HRAM and full-scan capabilities capture all sample data, all the time, enabling retrospective data analysis without the need to repeat experiments.
  • Resolving power up to 140,000 FWHM eliminates isobaric interferences, increasing confidence in results when analyzing samples in complex matrices.
  • Better than 1ppm mass accuracy in full and AIF scan modes ensures confident compound identification.
  • Fast scanning at 12Hz, suitable for UHPLC applications.
  • Rapid polarity switching maximizes information obtained.
  • AIF and multiple dissociation techniques, including in-source CID and HCD, aid in compound identification.
  • Extended mass range to 6,000m/z enhances detection of singly charged small molecules and biomolecules.
  • More than four orders of magnitude intrascan dynamic range and femtogram-level sensitivity enable detection of trace-level and high-abundance compounds in the same scan.

Easy-to-Use
  • HRAM and full-scan capabilities simplify MS method development.
  • Intuitive operating software reduces learning curve.
  • Compatibility with Thermo Scientific™ LCQUAN™, Mass Frontier™, and TraceFinder™ software speeds data analysis.

Upgradeable to Q Exactive
  • The Exactive Plus Orbitrap Mass Spectrometer can be upgraded on-site to the Q Exactive Hybrid Quadrupole-Orbitrap Mass Spectrometer with the addition of a high-performance quadruple for precursor ion selection.