Q Exactive™ HF Hybrid Quadrupole-Orbitrap™ Mass Spectrometer

Catalog number: IQLAAEGAAPFALGMBFZ
Thermo Scientific™

Q Exactive™ HF Hybrid Quadrupole-Orbitrap™ Mass Spectrometer

Catalog number: IQLAAEGAAPFALGMBFZ
Identify and quantify more proteins, peptides, lipids, glycans and small molecules accurately and in less time with the Thermo Scientific™ Q Exactive™ HF hybrid quadrupole-Orbitrap mass spectrometer. The Q Exactive HF system combines a state-of-the-art segmented quadrupole for high-performance precursor ion selection with a high-resolution, accurate-mass (HR/AM) ultra-high-field Orbitrap mass analyzer to deliver a superior combination of scan speed, resolving power, mass accuracy, spectral quality and sensitivity. Identify, quantify and confirm in a single analysis with a single instrument with the Q Exactive HF mass spectrometer.
 
Catalog Number
IQLAAEGAAPFALGMBFZ
Unit Size
Each
Scan Rates
Up to 18 Hz
Resolution
Up to 240,000 (FWHM) at <em>m/z</em> 200
Mass Range
50 to 6,000 m/z (up to 8,000 m/z with BioPharma Option)
Price (USD)
Full specifications
Mass Range50 to 6,000 m/z (up to 8,000 m/z with BioPharma Option)
TypeQuadrupole-Orbitrap LC-MS
Dynamic Range>5,000:1
Mass AccuracyInternal: <1 ppm RMS; External: <3ppm RMS
Polarity SwitchingOne Full Cycle in < 1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 60,000)
SensitivityMS/MS: 100 fg Reserpine on Column S/N 150:1, SIM: 50 fg Reserpine on Column S/N 150:1
ResolutionUp to 240,000 (FWHM) at <em>m/z</em> 200
Scan RatesUp to 18 Hz
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizeScan RatesResolutionMass RangePrice (USD)
IQLAAEGAAPFALGMBFZFull specifications
EachUp to 18 HzUp to 240,000 (FWHM) at <em>m/z</em> 20050 to 6,000 m/z (up to 8,000 m/z with BioPharma Option)Request A Quote
Mass Range50 to 6,000 m/z (up to 8,000 m/z with BioPharma Option)
TypeQuadrupole-Orbitrap LC-MS
Dynamic Range>5,000:1
Mass AccuracyInternal: <1 ppm RMS; External: <3ppm RMS
Polarity SwitchingOne Full Cycle in < 1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 60,000)
SensitivityMS/MS: 100 fg Reserpine on Column S/N 150:1, SIM: 50 fg Reserpine on Column S/N 150:1
ResolutionUp to 240,000 (FWHM) at <em>m/z</em> 200
Scan RatesUp to 18 Hz
Unit SizeEach
Showing 1 of 1
Advanced quadrupole technology for greater sensitivity and quantitative dynamic range

The Q Exactive HF instrument uses a segmented quadrupole mass filter to achieve more precise precursor isolation for better discrimination between analytes and coeluting interferences. An advanced active beam guide increases ion transmission. The result is superior sensitivity and greater quantitative dynamic range, especially when dealing with complex mixtures.

Multiple, sophisticated modes of data acquisition/quantitation ensure optimum quantitative results

The Q Exactive HF mass spectrometer supports multiple approaches to quantitation including selected ion monitoring (SIM), parallel-reaction monitoring (PRM), and data-independent acquisition (DIA). Users can select the technique best matched to their sample and information requirements.

  • SIM - selected ion monitoring provides simple method setup with maximum selectivity and sensitivity. It is ideal for quantifying small numbers of compound in samples of moderate complexity.
  • PRM - parallel-reaction monitoring provides high selectivity and high sensitivity with confident targeted confirmation. Quantitation is carried out post-acquisition for greater throughput. High-resolution, accurate-mass Orbitrap spectra ensure confident confirmation through library matching.
  • DIA - data independent acquisition enables large-scale targeted proteomics studies with qualitative confirmation. Its simple and universal acquisition set-up does not require detailed sample knowledge prior to data acquisition. DIA increases reproducibility and comprehensiveness with a complete record of quantitative data. It facilitates retrospective analysis of additional analytes.
Ultra-high-field Orbitrap mass analyzer increases resolving power and scan speed for greater productivity and higher confidence in less time

The Q Exactive HF system features a new ultra-high-field Orbitrap mass analyzer that, while physically smaller, provides higher resolution and faster scan speeds. Combined with the inherent superior quality of Orbitrap spectra, the Q Exactive HF system provides more-confident identification and quantitation in less time

  • Scan speed up to 18 Hz result in up to 50% more IDs from shorter gradients
  • Resolving power of up to 240,000 (FWHM) at m/z 200 ensures maximum ID confidence
  • Spectral quality significantly superior to Q-TOF mass spectrometers yields better protein coverage and quantitation results
  • Polarity switching (one full cycle in <1 sec at a resolution setting of 60,000) enables analysis of more, different compounds in a single analysis
Optional intact protein mode for enhanced analysis of intact proteins and protein complexes

When research requires analysis of intact proteins or protein complexes, the Q Exactive HF system can be equipped with an intact protein mode option (available on new instruments only). This option enhances analysis of intact proteins through sophisticated ion beam control and easy pressure adjustment.

Specifications, terms, and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.