Thermo Scientific™

Vanquish™ Column Compartments

Catalog number: VH-C10-A
Thermo Scientific™

Vanquish™ Column Compartments

Catalog number: VH-C10-A

Control your separation temperature with confidence using Thermo Scientific™ Vanquish™ Column Compartments. The unique combination of active and/or passive eluent pre-heating and two column thermostatting modes—still and forced air—available in Vanquish Column Compartments H and C, ensures reliable matching of the eluent and column temperature for superior UHPLC performance and allows for easy LC method transfer. Vanquish Column Compartment N supports advanced low-flow applications as well as capillary and micro-flow direct injection applications in the Thermo Scientific™ Vanquish™ Neo UHPLC system.

 
Catalog Number
VH-C10-A
Unit Size
Each
Description
Dimensions: 700 mm x 111 mm x 422 mm (27.6 in. x 4.4 in. x 16.6 in.), Weight: 14 kg (30.9 lb.)
For Use With (Equipment)
Vanquish UHPLC System
Price (USD)
Full specifications
DescriptionDimensions: 700 mm x 111 mm x 422 mm (27.6 in. x 4.4 in. x 16.6 in.), Weight: 14 kg (30.9 lb.)
For Use With (Equipment)Vanquish UHPLC System
TypeColumn Chamber: still and forced air; Pre-heater: active; Post-column Cooler: passive
Voltage100-240 V AC, 50/60 Hz, max. 202 W/326 VA
GLP FeaturesPredictive Performance functions for scheduling maintenance procedures based on the actual operating and usage conditions of the column compartment. All system parameters logged in the Chromeleon CDS Audit Trail.
Cool-Down TimeColumn Chamber: <15 min, 50°C to 20°C, ±1 K; Post-column Cooler: Down to 50°C (at 2 mL/min and 120°C column temperature (water/acetonitrile [50/50, v/v]))
Heat Up TimeColumn Chamber: <15 min, 20° to 50°C ± 1°K, Typical: 5 min, 25-40°C ± 1°K; Pre-heater: 80°C at 2.5 mL/min, 120°C (at 1 mL/min (water/acetonitrile [50/50, v/v]))
Column Capacity2 x max, 300 mm w/pre-heater or guard column, Max. ID: 10 mm; 2 x max, 250 mm w/pre-heater and guard column, Max. ID: 10 mm
Max. No. of Switching ValvesUp to 2 Valves: 2-position/6-port, 6-position/7-port
Biocompatible VersionYes, pH range 2-12, buffer and/or chloride concentration up to 1 mol/L
PC ConnectionUSB 2.0
Temperature AccuracyColumn Chamber: ±0.5 K (up to 80°C); Pre-heater: ±2 K; Post-column Cooler: ±2 K (up to 80°C)
Temperature StabilityColumn Chamber: ±0.05 K; Pre-heater: ±0.5 K; Post-column Cooler: ±0.5 K
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Vanquish Column Compartment H
For Use With (Equipment)
Vanquish Flex UHPLC System, Vanquish Horizon UHPLC System
Price (USD)
Full specifications
DescriptionVanquish Column Compartment H
For Use With (Equipment)Vanquish Flex UHPLC System, Vanquish Horizon UHPLC System
TypeColumn Compartment
Column Capacity2 x max, 300 mm w/pre-heater or guard column, Max. ID: 10 mm; 2 x max, 250 mm w/pre-heater and guard column, Max. ID: 10 mm
Temperature Range5 °C (max. 18 K below ambient) – 120 °C
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Vanquish Column Compartment C
For Use With (Equipment)
Vanquish Core HPLC System
Price (USD)
Full specifications
DescriptionVanquish Column Compartment C
For Use With (Equipment)Vanquish Core HPLC System
TypeColumn Compartment
Column Capacity2 x max, 300 mm w/pre-heater or guard column, Max. ID: 10 mm; 2 x max, 250 mm w/pre-heater and guard column, Max. ID: 10 mm
Temperature Range5 °C (max. 18 K below ambient) – 85 °C
Unit SizeEach
Showing 3 of 3
Catalog NumberSpecificationsUnit SizeDescriptionFor Use With (Equipment)Price (USD)
VH-C10-AFull specifications
EachDimensions: 700 mm x 111 mm x 422 mm (27.6 in. x 4.4 in. x 16.6 in.), Weight: 14 kg (30.9 lb.)Vanquish UHPLC SystemRequest A Quote
DescriptionDimensions: 700 mm x 111 mm x 422 mm (27.6 in. x 4.4 in. x 16.6 in.), Weight: 14 kg (30.9 lb.)
For Use With (Equipment)Vanquish UHPLC System
TypeColumn Chamber: still and forced air; Pre-heater: active; Post-column Cooler: passive
Voltage100-240 V AC, 50/60 Hz, max. 202 W/326 VA
GLP FeaturesPredictive Performance functions for scheduling maintenance procedures based on the actual operating and usage conditions of the column compartment. All system parameters logged in the Chromeleon CDS Audit Trail.
Cool-Down TimeColumn Chamber: <15 min, 50°C to 20°C, ±1 K; Post-column Cooler: Down to 50°C (at 2 mL/min and 120°C column temperature (water/acetonitrile [50/50, v/v]))
Heat Up TimeColumn Chamber: <15 min, 20° to 50°C ± 1°K, Typical: 5 min, 25-40°C ± 1°K; Pre-heater: 80°C at 2.5 mL/min, 120°C (at 1 mL/min (water/acetonitrile [50/50, v/v]))
Column Capacity2 x max, 300 mm w/pre-heater or guard column, Max. ID: 10 mm; 2 x max, 250 mm w/pre-heater and guard column, Max. ID: 10 mm
Max. No. of Switching ValvesUp to 2 Valves: 2-position/6-port, 6-position/7-port
Biocompatible VersionYes, pH range 2-12, buffer and/or chloride concentration up to 1 mol/L
PC ConnectionUSB 2.0
Temperature AccuracyColumn Chamber: ±0.5 K (up to 80°C); Pre-heater: ±2 K; Post-column Cooler: ±2 K (up to 80°C)
Temperature StabilityColumn Chamber: ±0.05 K; Pre-heater: ±0.5 K; Post-column Cooler: ±0.5 K
Unit SizeEach
VH-C10-A-03Full specifications
EachVanquish Column Compartment HVanquish Flex UHPLC System, Vanquish Horizon UHPLC SystemContact Us ›
DescriptionVanquish Column Compartment H
For Use With (Equipment)Vanquish Flex UHPLC System, Vanquish Horizon UHPLC System
TypeColumn Compartment
Column Capacity2 x max, 300 mm w/pre-heater or guard column, Max. ID: 10 mm; 2 x max, 250 mm w/pre-heater and guard column, Max. ID: 10 mm
Temperature Range5 °C (max. 18 K below ambient) – 120 °C
Unit SizeEach
VC-C10-A-03Full specifications
EachVanquish Column Compartment CVanquish Core HPLC SystemContact Us ›
DescriptionVanquish Column Compartment C
For Use With (Equipment)Vanquish Core HPLC System
TypeColumn Compartment
Column Capacity2 x max, 300 mm w/pre-heater or guard column, Max. ID: 10 mm; 2 x max, 250 mm w/pre-heater and guard column, Max. ID: 10 mm
Temperature Range5 °C (max. 18 K below ambient) – 85 °C
Unit SizeEach
Showing 3 of 3
Vanquish Column Compartments H and C offer:
  • Wide column temperature ranges with cooling down to 5 °C (max. 18 K below ambient)
  • Still-air thermostatting for minimum thermal mismatch by viscous heating for best possible efficiencies and resolution under UHPLC conditions
  • Forced-air thermostatting for fast thermal equilibration and highest flexibility, e.g., for method transfer from other instruments
  • Active eluent preheating and post-column cooling (Vanquish Column Compartment H only) for optimum separation control
  • Advanced workflows, such as Tandem LC and LC-MS, online SPE, trap and loop heart-cut 2D-LC with the installation of up to two optional switching valves
Vanquish Column Compartment N offers:
  • Passive pre-heating and forced-air thermostatting (column heating only)
  • Support for advanced low-flow applications as well as capillary and micro-flow direct injection applications with two optional low-dispersion switching valves
  • Optimized system stacking and capillary guiding for MS connection